Series 403X Storefront Installation Instructions

EFCO 2013

Page 19

INSTALL 1ST

SUBFRAME CLEARANCE HOLE =

[DOOR OPENING WIDTH + 4"]

2"

2"

Installation Notes:

 Correctly locate and install the door

frame into the opening as specified on
the shop drawings or architectural
drawings.

 End dams are not required at the door

frame end of a sill flashing.

 The sill flashing should butt up tight to

the door frame.

 See Fig. #18 for sill flashing to door

frame sealant requirements.

Section 4A. Door Frame Installation

Notes:



If NO door frame is required, proceed to Section 4B.



If a door frame is required, the frame must be installed first. All subsequent ladders must be

installed from the door frame out.



Door frame jambs do not set on sill flashing. Door jambs must run through to the floor condition.

Fig. #17

Fig. #18

Installation Notes:

 Before installing the sill

flashing, apply a bead of
silicone style sealant to the end
of the sill flashing.

 After Installation, tool excess

sealant into the joint where sill
flashing and door frame meet.

 At glazing pockets build-up

silicone sealant in pocket to the
tallest point of the sill flashing.
Tool the silicone sealant so a
watertight seal is made, and so
that water will be directed out of
the glazing pocket and into the
sill flashing.

 See Fig. #18 for sill flashing to

door frame sealant
requirements.

Sill Flashing