Series 403X Storefront Installation Instructions

EFCO 2013

Page 15

Section 3D. Expansion Mullions

Expansion mullions are required in elevations that are over 20’ - 25’ wide and can be used with both screw

spline and shear block systems.

 Do Not use expansion mullions at entrance jambs. Locate the expansion mullion at the next vertical mullion over so

that the distance between expansion mullions is never more than 25’-0”.

Screw Spline System Fabrication Steps:

1. Follow steps 1-3 in Section 3A for cut lengths and hole preparations.
2. Follow standard unit construction method.

Shear Block System Fabrication Steps:

1. Follow steps 1, 2, and 5 in Section 3B for cut lengths and hole preparations.
2. Follow standard unit construction.

Fig. #13

W104

Note:

Expansion Joint gap must be

maintained before anchoring unit.

W104

21S8 21S7