Troubleshooting, Tri-core, Lighthead flash pattern – Code 3 SuperVisor with TriCore for 2009 Chevy Tahoe User Manual
Page 7: Warning
7
Troubleshooting
All SuperVisor TLs are thoroughly tested prior to shipment. However, should you encounter a problem during installation or during the
life of the product, follow the guide below for information on repair and troubleshooting. Additional information may be obtained from
the factory technical help line at 314-996-2800.
Follow the guide below for information on repair and troubleshooting.
TROUBLESHOOTING GUIDE
Note: Tri-Core
TM
modules must be replaced as a module. There are no user serviceable parts.
PROBLEM
Tri-Core
TM
module not
operating when
powered.
QUESTIONS
POSSIBLE CAUSE
a. Bad power/ground
connection.
b. Defective module.
SOLUTION
a. Fix connection.
b. Replace module
N/A
Tri-Core
TM
Lighthead Flash Pattern
To change the flash patterns of the Tri-Core
TM
Lightheads, activate the Lightbar in the Level that is to be changed
and then momentarily touch the Green (Pattern Select) wire to +power. Repeating this procedure allows the operator
to cycle through the numerous flash patterns offered until the desired pattern is achieved. Repeat for all Levels as
needed.
To reset the flash patterns to the factory default, activate the Lightbar in any Level and then hold the Green (Pattern
Select) wire to +power for approximately 4 seconds.
Flash Patterns
Fast Alternating Quad Flash 100ms/25ms
Picket Fence Single Flash 200ms/25ms
Alternating Single Flash 200ms/25ms
Picket Fence Quad Flash 100ms/25ms
Picket Fence Six Flash 75ms/25ms
Slow Alternating Quad Flash 150ms/50ms
Slow Alternating Six Flash 125ms/25ms
Fast Alternating Six Flash 75ms/25ms
Variable Rate Picket Fence, Single Flash
Alternating Quad Flash, 80 FPM, NFPA Compliant
Cycle Flash
Simultaneous Quad Flash 75 FPM NFPA Compliant
Null Flash (nothing flashing - steady burns only)
This Product contains high intensity LED devices. To prevent eye damage,
DO NOT stare into light beam at close range.
This Product contains high intensity Tri-Core
TM
devices. To prevent eye
damage,
WARNING!
Any Disassembly of any of the Tri-Core Modules will result in loss of
warranty coverage on the equipment.
WARNING!