ArrowStik® Modules
Selecting the ArrowStik Pattern
The Central Controller is designed to offer user selectable traffic directing and traffic warning flash patterns. Each of the ArrowStik functions (LEFT,
CENTER-OUT, RIGHT or FLASH) can be programmed individually for unique patterns and flash rates. This allows the greatest flexibility when
controlling the various light bar configurations available. The light bar can be ordered with a 5, 6, 7 or 8 lighthead configuration. The light bar
will come from the factory with the Building Fast pattern as the default for LEFT, CENTER-OUT and RIGHT. The default pattern for FLASH is the
Standard Flash. If it is desired to change the pattern for any of the functions, follow the programming procedure below.
STEP 1:
Power-up the light bar. Select the ArrowStik function that you wish to program (LEFT, CENTER-OUT, RIGHT or FLASH).
Make sure +12v is only applied to the function you are trying to program - otherwise program function will not
operate.
STEP 2:
Continue applying power to the wire from Step 1. Refer to Table 2 for the available flash patterns.
Scroll to the next flash pattern by momentarily holding the Pattern Select wire (BLK/RED) to +power for ~1 sec. The light bar will stop flashing when
the wire is connected to +power. Release the wire and the next pattern as listed in Table 2 will begin to flash. The new pattern is automatically
stored each time.
Notice that for the LEFT, CENTER-OUT and RIGHT functions there are four pattern choices (Building, Building with 3 Flash for the end lightheads,
Traveling Ball with 3 Flash for the end lightheads, and Build/Collapse) and three speeds (Fast, Medium and Slow). There are a total of twelve
possible selections for each function and then you return to the top selection.
For the FLASH function there are nine traffic warning patterns available. Flash patterns marked with an asterisk “*” can be selected in Fast, Medium
or Slow flash rate.
NOTE: To restore the Factory Default ArrowStik Flash Patterns, hold the BLK/RED wire to +power for ~four
seconds.
STEP 3:
Repeat steps 1 through 2 for the other ArrowStik functions as desired.
TRAFFIC DIRECTINg / TRAFFIC wARNINg FLASh PATTERNS
Mode
LEFT
CENTER-OUT
RIghT
FLASh
1
Building
Building
Building
Standard Flash*
2
Building, 3 Flash
Building, 3 Flash
Building, 3 Flash
Quad Flash Standard
3
Traveling Ball, 3 Flash
Traveling Ball, 3 Flash
Traveling Ball, 3 Flash
Simultaneous Flash*
4
Build/Collapse
Build/Collapse
Build/Collapse
Quad Flash Simultaneous
5
Even/Odd Flash*
6
Quad Flash Even/Odd
7
Left/Right Flash*
8
Quad Flash Left/Right
9
Traveling Ball Flash*
All Patterns have a fast,
medium, or slow speed.
All Patterns have a fast,
medium, or slow speed.
All Patterns have a fast,
medium, or slow speed.
Patterns with the * have a fast,
medium, or slow speed.
Table 2