beautypg.com

Code 3 RX 2700CC User Manual

Page 5

background image

LED DIRECTIONAL MODULES

In addition to the 360° warning modules the lightbar may be equipped with a number of single head front-rear warning LED modules. These modules

are available in either the, PriZm 8-LED Reflector, PriZm 3-LED Reflector, 3-LED OLP OPTIX (dual stack 3-LED lightheads).

Operating Specifications for front-rear module:

Operating Voltage: 10-16 VDC, Reverse Polarity Protection

Current Draw : Standby 16ma

Flashing Module:

Red/Amber - .25A avg @ 12.8 Volts

Blue/White - .4A avg @ 12.8 Volts

Steady Burn Module:

Red/Amber - .5A avg @ 12.8 Volts

Blue/White - .8A avg @ 12.8 Volts

Available Colors: Red , Blue, Amber, and White

The flash pattern for these modules is chosen by the following procedure:

Selecting Flash Patterns

The Pattern Select wire is the BLK/RED wire in the sixteen conductor lightbar control cable and is activated by momentarily touching the wire to

+power.

STEP 1

Power-up the lightbar and select the Level-1 flash mode by applying +power to the GRN/BLK wire in the 16 conductor control cable.

STEP 2

Observe the flashing pattern operation and determine which pattern is in operation for Level-1. Refer to Table 1A. This table shows the available

flash patterns. Note: the Factory Default is different and identified in the table for each of the flash mode Levels (L1, L2, L3). Once the flash pattern

has been determined, proceed to Step 3.

STEP 3

Scroll to the next flash pattern by momentarily holding the Pattern Select wire (BLK/RED) to +power for ~1 sec, until the lightbar LEDs switches flash

patterns, and then releasing it. This will step to the next pattern in numbered order as listed in Table 1A for the selected 3-Level mode. The new

pattern is automatically stored each time. Repeat this procedure for Level-2 and Level-3.

Note: HOLD the Pattern Select wire to the +POWER source for about 1 second and release then observe that the flash pattern has

changed to the next pattern in the sequence. To restore the Factory Default Emergency Warning Flash Patterns, hold the Pattern Select

wire on the +POWER source for ~four (4) seconds while L1, L2 or L3 is enabled.

Note: All control inputs are +power enabled.

Control Input Function Definitions

Wire Color

Function

Description

GRN/BLK

Level 1

Level 1 Emergency Mode

WHT/BLK

Level 2

Level 2 Emergency Mode

RED/BLK

Level 3

Level 3 Emergency Mode

ORG/BLK

Takedown lights

Takedown Lights Steady Burn (overrides Takedown Flash)

BLU/BLK

Rear Cut-Off

Blacks-Out Rear Facing LEDs

GRN/WHT

Front Cut-Off

Blacks-Out Front Facing LEDs

RED/WHT

Right Alley Light

Right Alley Steady Burn (overrides Alley Light Flash)

BLK/WHT

Left Alley Light

Left Alley Steady Burn (overrides Alley Light Flash)

WHT

ArrowStik Flash

ArrowStik Flash (overrides L1, L2 & L3 for rear of light bar)

BLK/RED**

Pattern Select

Pattern Select for ArrowStik, L1, L2 & L3, enables test mode)

BLK

Takedown Flash

Enables Takedown Lights Wig/Wag Flash

RED*

ArrowStik Left

Left ArrowStik (overrides L1, L2 & L3 for rear of light bar)

GRN

Cruise Lights

End LEDs only (overridden by all other functions)

ORG*

ArrowStik Right

Right ArrowStik (overrides L1, L2 & L3 for rear of light bar)

BLU

Light bar DIM

Sets LED to Dim mode

BLU/WHT

Alley Light Flash

Enables Alley Light Wig/Wag Flash

5