Code 3 RX 2700CC User Manual
Page 5
LED DIRECTIONAL MODULES
In addition to the 360° warning modules the lightbar may be equipped with a number of single head front-rear warning LED modules. These modules
are available in either the, PriZm 8-LED Reflector, PriZm 3-LED Reflector, 3-LED OLP OPTIX (dual stack 3-LED lightheads).
Operating Specifications for front-rear module:
Operating Voltage: 10-16 VDC, Reverse Polarity Protection
Current Draw : Standby 16ma
Flashing Module:
Red/Amber - .25A avg @ 12.8 Volts
Blue/White - .4A avg @ 12.8 Volts
Steady Burn Module:
Red/Amber - .5A avg @ 12.8 Volts
Blue/White - .8A avg @ 12.8 Volts
Available Colors: Red , Blue, Amber, and White
The flash pattern for these modules is chosen by the following procedure:
Selecting Flash Patterns
The Pattern Select wire is the BLK/RED wire in the sixteen conductor lightbar control cable and is activated by momentarily touching the wire to
+power.
STEP 1
Power-up the lightbar and select the Level-1 flash mode by applying +power to the GRN/BLK wire in the 16 conductor control cable.
STEP 2
Observe the flashing pattern operation and determine which pattern is in operation for Level-1. Refer to Table 1A. This table shows the available
flash patterns. Note: the Factory Default is different and identified in the table for each of the flash mode Levels (L1, L2, L3). Once the flash pattern
has been determined, proceed to Step 3.
STEP 3
Scroll to the next flash pattern by momentarily holding the Pattern Select wire (BLK/RED) to +power for ~1 sec, until the lightbar LEDs switches flash
patterns, and then releasing it. This will step to the next pattern in numbered order as listed in Table 1A for the selected 3-Level mode. The new
pattern is automatically stored each time. Repeat this procedure for Level-2 and Level-3.
Note: HOLD the Pattern Select wire to the +POWER source for about 1 second and release then observe that the flash pattern has
changed to the next pattern in the sequence. To restore the Factory Default Emergency Warning Flash Patterns, hold the Pattern Select
wire on the +POWER source for ~four (4) seconds while L1, L2 or L3 is enabled.
Note: All control inputs are +power enabled.
Control Input Function Definitions
Wire Color
Function
Description
GRN/BLK
Level 1
Level 1 Emergency Mode
WHT/BLK
Level 2
Level 2 Emergency Mode
RED/BLK
Level 3
Level 3 Emergency Mode
ORG/BLK
Takedown lights
Takedown Lights Steady Burn (overrides Takedown Flash)
BLU/BLK
Rear Cut-Off
Blacks-Out Rear Facing LEDs
GRN/WHT
Front Cut-Off
Blacks-Out Front Facing LEDs
RED/WHT
Right Alley Light
Right Alley Steady Burn (overrides Alley Light Flash)
BLK/WHT
Left Alley Light
Left Alley Steady Burn (overrides Alley Light Flash)
WHT
ArrowStik Flash
ArrowStik Flash (overrides L1, L2 & L3 for rear of light bar)
BLK/RED**
Pattern Select
Pattern Select for ArrowStik, L1, L2 & L3, enables test mode)
BLK
Takedown Flash
Enables Takedown Lights Wig/Wag Flash
RED*
ArrowStik Left
Left ArrowStik (overrides L1, L2 & L3 for rear of light bar)
GRN
Cruise Lights
End LEDs only (overridden by all other functions)
ORG*
ArrowStik Right
Right ArrowStik (overrides L1, L2 & L3 for rear of light bar)
BLU
Light bar DIM
Sets LED to Dim mode
BLU/WHT
Alley Light Flash
Enables Alley Light Wig/Wag Flash
5