beautypg.com

Troubleshooting – Code 3 RMX Lightbar User Manual

Page 11

background image

11

PROBLEM

LED directional or
entire corner module
not operating when
powered.

LED corner module
has one head out.

LED corner module
has one head out.

Dimming does not
operate.

POSSIBLE CAUSE

a. Bad power/ground
connection.
b. Defective module.

a. See next

a. In front cut-off mode.
Proper functioning.
b. Check white wire between
master/slave modules for

damage or disconnection.
c. Check power and ground
of front module.

a. See next

a. No power to master.
Master(Rear) must be
powered for slave(front)
to operate.

b. Failed master.

a. White wire on module not
connected to source of +12V.

SOLUTION

a. Fix connection.

b. Replace module.

a. No problem

b. Fix white wire/connection.

c. Fix power/ground

connection.

a. Check power/ground

connections.

b. Replace entire 360

module.

a. Connect white wire to +12V source.

LED MODULE

TROUBLESHOOTING GUIDE

Troubleshooting

All RMX™ Lightbars are thoroughly tested prior to shipment. However, should you encounter a problem during installation or during
the life of the product, follow the guide below for information on repair and troubleshooting. Additional information may be obtained
from the factory technical help line at 314-996-2800.

Note: LED modules must be replaced as a module. There are no user serviceable parts.

QUESTIONS

Are both heads on
a corner module or
a single head on a
directional module
out?

Yes

No

Is the rear head
fl ashing and the
front head out?

Yes

No

Is the front head
steady burning and
the rear
head out?

Yes

No

N/A