beautypg.com

Introduction, Standard features, Specifications – Code 3 PSE460H Remote Strobe Power Supply User Manual

Page 2

background image

Introduction

The 460H Series Remote Power Supply represents the latest in state-of-the-art strobe warning technology.
The latest in MOSFET technology and advanced design provide efficient operation, meaning superior
performance, reliability and long life. The use of intelligent microprocessor control allows the model 460H to
offer more light pattern options and versatility than any other remote system available. The user may select
the standard Quad Flash pattern or any of five additional auxiliary patterns. In addition, the user can utilize all
flash options with Cycle Flash

TM

a feature that allows cycling continuously through all patterns. When

connected to PSE's line of oval and round remote strobe heads, remote 360 beacon, and accessories the
460H delivers an outstanding level of vehicle warning signals.

Standard Features

All MODEL 460H Remote Strobe Power Supplies come equipped with the following standard features:
(See Figure 2, page 5)

MULTIPLE OPERATING VOLTAGES
10-30 VDC operation only. Reverse polarity protected

EXTERNAL FUSE PROTECTION
User replaceable 15 AMP fuse for +12 VDC operation.
NOTE: For +24 VDC operation, the user should replace this with a 7.5 AMP fuse.

OUTPUT SHORT CIRCUIT/FLASHTUBE FAILURE PROTECTION
Power supply will shut-off when trying to flash any heads that have been shorted, or have a failed flash tube.

MULTIPLE USER SELECTABLE FLASH PATTERNS
User may select either Quad Flash, Double Flash, Fast Double flash, Triple Flash, Five Flash, or Cycle Flash
patterns. See Flash Control Options Section, page 7.

SELECTABLE SWITCHING CONTROL OF OUTLET PAIRS
Allows user, when in the standard Quad Flash mode, to select either alternating outlet pairs 1 and 4 only, or 2
and 3 only.
NOTE: Additional auxiliary flash modes utilize all outlets, 2 outlets alternate with 2 outlets. There is no select-
able switching available.

HI/LO POWER CONTROL
Allows reduction of strobe light intensity using either +VDC or (earth) ground switching for night time use.

LOW CURRENT SWITCHING, SEE PAGE 10

Specifications

OPERATING VOLTAGE: 10-30 VDC

OUTPUT POWER: 60 WATTS NOMINAL

OUTPUT ENERGY: 60 JOULES NOMINAL

STANDARD FLASH RATE:

EACH STROBE LIGHT OUTLET

60 QUAD FLASHES/MIN.

ALTERNATING PAIRS

120 QUAD FLASHES/MIN.

POWER CONSUMPTION:

6 AMPS AVERAGE AT 12.8 VDC (HIGH POWER)
3 AMPS AVERAGE AT 25.6 VDC (HIGH POWER)