Programming:

Programming the desired flash pattern (or operation mode ) is done with the white control
wire. You can scroll through the eight available flash patterns, by momentarily grounding the
white control wire until you arrive at the desired operation mode. Momentary grounding of
the white wire can be accomplished either by momentarily touching the wire to GND, or
through a momentary push-button switch.
The unit will come on in the default Cycle-flash mode at the time of first power-up, until the
desired flash pattern is programmed. The default flash pattern can then be changed by
programming the desired pattern into the unit, the unit will continue to operate in the same
mode every time the unit is turned off and turned back on. The default flash pattern can be
changed at will for any number of times.
The unit can be reset back to the default flash pattern ( cycle-flash ) by grounding the control
wire for about 8-10 seconds and then releasing it. This can be done while operating in any
of the flash modes.

Steady-Burning (Non-Flashing) Models:

These models are supplied with only two wires. Red power wire and black GND wire. The
third (white) wire is not available on these models.
Connect the wires as follows:

1. Red wire: Power wire, connect to +12V voltage line.
2. Black wire: GND wire, connect to Ground terminal.

STT (Stop-Turn-Tail) Models:

These models are equipped with a 8" long 3-wire cable harness. The user is required to
furnish terminals according to his or her preference. Connect the wires as follows:

1. Red wire: Power wire, connect to +12V voltage line.
2. Black wire: GND wire, connect to a ground terminal.
3. White wire: Stop-Light trigger input, grounding this wire will result in high-intensity

operation. This wire may be connected to an active low brake-light trigger
output if available.

8