Ix. warranty, terms & conditions – BoonDocker POLARIS: 700/800 IQ Dragon Plug & Play User Manual
Page 13
BoonDocker – 1585 Hollipark Dr. Idaho Falls, ID 83401 – 208-542-4411 / 877-522-7805
www.boondockers.com – email:
– fax: 208-524-7381
Revised 1-16-08
Page 13 of 13
2. Verify that all wiring is in good condition and that the wires have not pulled out of the terminals. To verify this, look
inside each connector and verify that the terminal pins are all at the same height. If a terminal is starting to back out,
it will appear to be lower in the connector.
3. Unplug the EFI harness and plug original harness back into the injectors and verify that the sled runs OK (test can
only be done at low rpms before boost comes on).
4. If problem only occurs with Control Box plugged in, change all fuel adjustment settings to 0 and see if problem
persists.
5. Verify that the Control Box does not reset itself when the sled is running by doing the following:
a. When the sled is first powered up, change the menu screen on the Control Box to one of the fuel adjust
screens.
b. Run the sled.
c. Before shutting off the sled, verify that the screen is still on the same menu selection.
d. If the startup screen is displayed (showing version number etc.), the box has reset itself. This is likely
caused by bad voltage to the box due to an intermittent connection.
Rough Idle
Idle adjustments are much more sensitive than other adjustments since the injectors are on for a very
short duration. You may not be able to adjust your 3000 LO settings by very much.
LCD is dim
If you are using a 9 volt battery to power the box when the sled is not running, your battery voltage is
getting low – replace your battery. Extreme hot or cold temperatures may cause the LCD to not
display properly.
LCD display is slow
Cold weather conditions can make the LCD respond very slowly. The Control Box will still function
OK. You can locate the box under the hood in order to provide heat so the LCD will display quicker.
Moisture on LCD
Condensation is normal if the Control Box is quickly moved from a cold to a warm environment. In
some cases, the Control Box enclosure may no longer be sealing properly. If such problems persist,
contact Boondocker to determine if resealing the box is necessary.
Check Engine light
Make sure the wires in the EFI harness are correct and check for a bad connection in the wiring
harness. Recheck all connectors and be sure each is completely latched. Also inspect each wire to
make sure there are no frayed, broken, or melted wires.
IX. Warranty, Terms & Conditions
Returned Goods – No merchandise will be accepted without prior approval. A RMA number (Return Merchandise
Authorization) provided by Boondocker is required before a return will be accepted. A 20% handling and restocking charge
will be applied to returned merchandise. No unauthorized returns will be accepted.
Limited Warranty – Boondocker warrants its product to the original purchaser against workmanship defects for a period of
90 days, commencing from the date of product delivery to the Consumer.
Maximum Liability – The maximum liability of Boondocker in connection with this warranty shall not under any
circumstances exceed the price of the product claimed to be defective.