beautypg.com

Fig.11 5 the meaning of some displayed symbols, 6 trouble shooting – Salter Brecknell RD-65 Remote Display User Manual

Page 16

background image

14

Fig.11

5 The meaning of some displayed symbols:

1) Err01:no communication
2) Err02:incorrect format data received.
3) Err03: over displaying range
4) ¯¯¯¯¯ :over range
5)

______:below range

6 Trouble shooting

Problem

Possible cause

Check

No display

1)fuse damaged
2)adaptor damaged

Replace fuse or adaptor

Display too dark

1) Low voltage
2) Inner part damaged

Check the input voltage and
replace the damaged part or
main PCB

Err01
(no communication)

1) RD65 data format is different from the host
2) Communication cable is not connected
correctly.

Check cable and the data

format setup

Err02
( in-correct format
data received)

1)Format switch is not set correctly.
2)Host is not set correctly.
3)unknown host or data format used on host
device

Check whether the protocol
is matched between RD65
and Host.

Remote Display

Lock nut

expansion bolt

expansion bolt

Suspension arms