3 user configuration settings, User configuration settings – Salter Brecknell SBI100 User Manual
Page 21
SBI 100 User Instructions Manual
19
4.3 User Configuration Settings
Parameter
Description
Settings
(default in bold)
P1.xy
Auto shutoff timer in minutes
Set up time for the auto off function.
(00 = 0ff, 01-15 = time in minutes)
P1.00
P1.01 - P1.15
P1.5 = 15 minutes
P2.x
Hold and print key functionality
Setup button function
0 = Press button once to activate hold
1= Press button once to print
2= Press button to print/Press and hold button to activate hold.
P2.0= Hold
P2.1= Print
P2.2= Print & Hold
P3.xy
Hold Function Settings
0= No hold function active
1= Averaging hold with manual push button release
The weight reading will be held on the display until a higher weight is applied, this will
automatically release the held weight and re-hold it at the new higher weight reading.
2= Averaging hold with automatic release and re-hold
Same as above but the weight reading will be held on the display until the platform is
emptied and the next weight reading over 10 divisions is applied.
3-50= Selectable hold window from +/- 3 to 50 divisions
Will hold display reading once stable within a selectable weight range, to release the hold
button must be repressed.
P3.0
P3.1
P3.2
P3.3 to 50
P4.x
RS232 - Serial Interface
Settings for serial interface
0= No RS232 output
1= Print displayed data once stable when print key is pressed
2= Print gross, tare and net weight once stable when print key is pressed
3= Continuously output gross weight
4= Continuously output gross, tare and net weight
5= Print displayed data once stable one time only.
6= Print gross, tare and net weight once stable, one time only.
7= Bidirectional - RS232, SBI protocol
P4.0
P4.1’
P4.2
P4.3
P4.4
P4.5
P4.6
P4.7
P5.x
RS232 Baud rate
P5.0= 1200
P5.1= 2400
P5.2= 4800
P5.3= 9600
P5.4= 19200
P6.x
RS232 Data format
0 = 8 digits, no odd or even, 1 start bit, nan1 stop bit
1 = 7 digits, 1 even, 1 start bit, 1 stop bit
2 = 7 digits, 1 odd, 1 start bit, 1 stop bit
3 = 8 digits, no parity, 1 start bit, 1 stop bit
P6. 0
P6. 1
P6. 2
P6. 3
P7-P19.x
SERVICE CONFIGURATIONS ONLY
Any adjustment to these settings could seriously affect the indicators performance. Seek advice from a
service engineer before changing.