PS1000/2000 User Instructions

7

2.2.2 Dimension

l

6.5” L x 3.2” H x 1.2” W

m

164 mm (L) x 762 mm (W) x 64 mm (H)

2.2.3 Display

l

5-digit,7-segment, 0.625" (16mm) LCD

2.2.4 Keypad

l

4 push button keys

2.2.5 Environment

2.2.6 Load Cell Excitation

Because more than one load cell can be used on a scale, the following are required for
the load cell set to be used with this indicator.

2.2.7 Communication

Working temperature

5° to 35°C

Storage temperature

-10°C to 70°C

Humidity

≤95% RH without condensation

Voltage

4.4VDC

Max. Current

55mA (can power 4-350 ohm loadcells)

Signal connection

4 or 6 lead with sense leads

Max Sensitivity

0.3mV/V to +3mV/V (must be fit to >0.2µV

/

display grad)

Input Resistor

≥80 Ω

Output Resistor

<10 KΩ

Mode

Full-duplex or only output mode can be selected

Baud Rate

Selectable: 1200-2400-4800-9600-19200 bps

Data Format

7 data bits, even or odd parity, 1 stop bit
8 data bits, non-parity, 1 stop bit

Protocol

7 selected protocols (one compatible with NCI standard SCP-01)

Output Data

gross weight, net weight, tare weight, indicator displaying weight, weighing unit etc.

This manual is related to the following products: