TROUBLE SHOOTING

Symptom

Recommended Action

After pressing the “WT HOLD”

Key and placing a weight on the

scale, the weight will not hold in
the display. The “ ” continues to

flash

Remove weight from scale and place the

Weight in the center of the scale

OR

The scale is not in a stable environment that

allows the weight hold feature to work.

Remove the item and place it back onto the

scale

OR

Not enough weight is applied for the weight

hold to work, minimum weight required is 1

pound

“ErrE” is displayed

Software error, turn the scale off then on

again

“8888” is displayed

Software error, turn the scale off then on

again.

OR

Zero key is stuck. Gently free ZERO button

Unit will not stay on

Auto Power Off is activated, See page 5 for

configuration.

Backlit display does not work

Display is broken

I lost my power supply and

battery cover

Contact the factory at 1-800-637-0529 for

replacement parts.

Incorrect Hold Weight

Scale was not able to stabilize and

determine a hold weight, repeat hold.

OR

Hold key is stuck, gently free HOLD button

From sticking into base off scale.

OR

Item was not placed on the scale quick

enough.

9

GENERAL FEATURES and FIRST TIME USE INSTRUCTIONS

The GP family of bench scales is intended to be used as a general purpose,

portable bench scale to weigh objects or packages for determining shipping weights

and

weight verification. The GP series is not intended for “Legal for Trade” applications.

Salter Brecknell offers other “Legal for Trade” scales, you can visit our web-site at

www.salterbrecknell.com.

The GP series bench scales offers some unique features:

Auto Power Off – The unit is factory configured for the unit to shut off after 2

minutes of non-use. This feature is designed to save the battery and backlit

display life. If the scale is going to be powered via the AC adapter and you would

like to disable the Auto Power Off feature, see page 5 for detailed instructions.

Units – This feature is factory configured for the “UNITS” switching feature to be

active. The “UNITS” key allows you to weigh or compare weights in Pounds (LB) or

Kilograms (KG). When powering the scale on, the units of measure default, LB or

KG, will be used depending on your country of origin. The displayed weight being

used can be identified by checking to make sure the bullet on the display is pointing

to LB or KG. See page 7 for detailed instructions on changing the default units of

measure or deactivating the “UNITS” button.

TARE – The tare feature is used when you want to weigh items on the scale while

using an empty container to hold them in place on the scale. Simply place the empty

container on the scale, press the “TARE” key, the scale will now display “0.0” weight.

Place your items in the empty container to obtain the actual weight of the items in

the container. See page 3 for detailed instructions.

HOLD – The Weight HOLD feature is used when you have a object placed on the

scale that is to large for you to view the weight on the display. Pressing the “HOLD

button prior to placing the object on the scale will activate the hold feature. Once the

item is placed on the scale for 2-5 seconds, remove the object and the scale will

display the average weight of the item. See page 4 for detailed instructions.