beautypg.com

Salter Brecknell LPS30 User Manual

Page 17

background image

P7.xy

00-31

10

Resolution select: 500,600,750,800,1000,1200,
1500,2000,2400,2500, 3000, 3500, 4000, 5000,
6000, 7000, 7500, 8000, 10000, 12000, 15000,
20000, 25000, 30000, 35000, 40000, 50000,
60000,70000,75000,80000,100000

P8.x

0,1, 2

1

Division select: 0=1, 1=2, 2=5

P9.x

0,1,2,3,4,

5

1

Decimal point in calibration: 0=Ч1, 1=Ч0.1,
2=Ч0.01; 3=Ч0.001; 4=Ч0.0001; 5=Ч10

P10.x

0, 1

1

Calibration unit: 0=kg, 1=lb

P11.x

0, 1, 2, 3,

4, 5, 6

6

Weighing units enable: 0=only kg; 1=only lb;
2=only lb:oz; 3=kg or lb; 4=kg or lb:oz; 5=lb or
lb:oz; 6=kg, lb, or lb:oz

P12.x

0, 1, 2, 3,
4, 5, 6, 7,

7

Power-on zero-point range:
0=calibration zero -point +1%FS;
1=calibration zero -point +2%FS;
2=calibration zero-point +5%FS;
3=calibration zero-point +10%FS;
4=calibration zero-point +20%FS;
5=calibration zero-point +50%FS;
6=calibration zero-point +100%FS;
7=No limitation

P13.x

0,1,2,3,4,

5,6,7,8,
9,10,11,
12,13,

14,15

4

Zero range for ZERO button:
0= Power-on zero-point +1%FS;
1= Power-on zero-point +2%FS;
2= Power-on zero-point +3%FS;
3= Power-on zero-point +4%FS;
4= Power-on zero-point +5%FS;
5= Power-on zero-point +10%FS;
6= Power-on zero-point +20%FS;
7= Power-on zero-point +No limitation
8= Power-on zero-point +1%FS;
9= Power-on zero-point +2%FS;
10= Power-on zero-point +3%FS;
11= Power-on zero-point +4%FS;
12= Power-on zero-point +5%FS;
13= Power-on zero-point +10%FS;
14= Power-on zero-point +20%FS;
15= Power-on zero-point +No limitation

28

P14.x

0, 1, 2

0

Weight signal within power-on zero point range,
Choose which data as current power-on zero
point; 0= current weight ; 1= calibration
zero-point; 2=switch-off zero-point

P15.x

0, 1, 2

1

Weight signal not within power-on zero point
range, Choose which data as current power-on
zero point; 0= current weight ; 1= calibration
zero-point; 2=switch-off zero-point;
3=continuously display “0ˉˉˉˉ”

P16.x

0, 1, 2, 3,

4, 5, 6,7,8

4

Zero tracking range: 0=0d, no tracking;
1=+0.25d; 2= +0.5d; 3=+1d; 4=+1.5d; 5=+2d;
6=+3d; 7= +4d; 8=+5d

P17.x

0, 1, 2, 3

2

Data filter intensity: 0=very weak, 1=weak,
2=middle, 3=strong

P18.x

0, 1….9

1

Check weight stability range: 0=+0.5d;
1= ± 1d ; 2=+1.5d; 3=+2d; 4=+3d; 5=+4d ;
6=+5d ; 7=+6d ; 8=+7d; 9=+8d

P19.x

0, 1….9

3

Overload limit range: 0=FS+0d; 1=FS+9d;
2=101%FS; 3=102%FS; 4=105%FS;
5=110%FS; 6=120%FS; 7=150%FS;
8=200%FS; 9=No limitation
















29