AVer EXR6004-Mini user manual User Manual
Page 57

51
-
Start Recording
Record the video from the selected camera.
1. Next to the Start Recording check box, click
Detail.
2. In the Alarm Recording Setting dialog box,
select the camera to enable/disable video
recording. Enable All to select all cameras.
3. In the Frame Rate selection, select As Setting
to record the number of frames based on the
Recording Setting.
4. In the Start Record prior text box, mark and
set the number in second for the program to
begin recording after the alarm has been
trigger. The time range is 1~10 seconds.
5. In the Stop Record after text box, mark and set the number in second for the program to
continue recording after the alarm has ended. The time range is 1~999 seconds. If user doesn
’t
mark and set the time, the alarm recording will continue recording until alarm is reset.
6. Click OK to accept the new settings and Cancel to exit without saving.
- PTZ preset point
- Position the PTZ camera based on the preset
point setting. Beside the PTZ preset point check
box, click Detail. In the Trigger PTZ Preset Setting
dialog box, select the PTZ camera number then
select the Enable check box. Select the position
of the PTZ camera when the alarm is activated
and ended. For the PTZ camera end point, user
can also select on preset position or Auto Pan
between preset position groups.
- Send to CMS (Central Management System)
Enable/disable the selected camera to send video to
CMS when the alarm is activated.
Next to the Send to CMS check box, click Detail. In the
CMS Setting, select the camera to enable/disable
sending the video to CMS. Enable All to select all
cameras. Then, click OK to accept the new settings and
Cancel to exit without saving.