28
of Stream 2and Stream 3 on the selected IP camera channel. The Stream 1 is stetted in
default.
Stream Selection: user can setup which stream (Stream 1 ~ Stream 3) to use on Record,
Preview(Quad and Single mode), and Remote site.
Video Adjustment: user can adjust Brightness and Contrast of IP camera.
The stream setting only support for AVer IP camera series.
I/O Control: Setup the sensor and relay that is embedded on the IP camera.
Sensor Setting
1. Click Sensor button.
2. Click the drop-down list and select the sensor ID
number.
3. Enter sensor name in Name column
4. The system automatically detects the camera and input
relates information. In the Content section, enter
sensor Description.
5. In the test section, click Test to check the sensor status.
Red is high and Green is low.
6. Click OK to exit and accept the setting and Cancel to
exit without saving the setting.
Relay Setting
1.
Click Relay button.
2.
Click the drop-down list and select the relay ID
number.
3.
Enter relay name in Name column
4.
The system automatically detects the camera and
input relates information. In the Content section, enter
relay Description.
5.
In the test section, click Test to check the relay status.
Red is high and Green is low.
6.
Click OK to exit and accept the setting and Cancel to
exit without saving the setting.