Self-diagnosis display
The camcorder has a self-diagnosis display-
This funclion displays the camcorder's condition
with five digits (a combination of a letter and
figures) in the viewfinder or in the display. If this
occurs, check the following code chart. The five
digit display informs you of the camcorder's
current condition. The last two digits (indicated
by □□) will differ depending on the state of the
camcorder.
Viewfinder
-C:21:00
•'/Mil'.'
Self-diagnosis display
You can service the camcorder
yourself.
•E:nn:DD
Contact your Sony dealer or local
autorized Sony facilitiv.
>
a
a
Five-digit display
Cause and/or Corrective Actions
C:21:DD
• Moisture condensation has occurred.
■> Remove the cassette and leave the camcorder for at least
1 hour. (p. 62)
C:22:Dn
• The video heads are dirty.
Clean the heads using the Sony V8-25CLH/V8-25CLD
cleaning cassette (not supplied), (p. 63)
C:23:Dn
• You are using a battery pack that is not an
"InfoLlTHIUM" battery pack.
Use an "InfoLlTHIUM" battery pack. (p. 61)
C:31:an
C:32:Dn
• A servicable situation not malfunctioned above has
occurred.
■f Remove the cassette and insert it again, then operate the
camcorder.
■> Disconnect the power cord of the AC power adaptor or
remove the battery pack. After reconnecting the power
source, operate the camcorder.
E:61:Dn
E:62:DD
• A camcorder malfunction which you cannot service has
occurred.
■> Contact your Sony dealer or local authorized Sony
service facility and inform them of the five digits,
(example: E:61:10)
If you are unable to resolve the problem, contact your Sony dealer or local authorized
Sony service facility.