PHOTOMETRICS

ORDERING INFORMATION

SHIPPING DATA

2BX40

2AC

C o e ffi c i e n t s o f U t i l i z a t i o n

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

10%

0%

rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

RCR

0
1
2
3
4
5
6
7
8
9

10

Z o n a l L u m e n S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-180

||

C a n d e l a

Angle

Along II

45°

Across

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

2AC-2BX40
Electronic Ballast
(2) F40BX lamps
3000 lumens
Spacing criterion:
(II) 1.3 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 79.6%
Test Report:
241P137
LER = FL-58
Yearly Cost of 1000
lumens, 3000 hrs
at .08 KWH = $4.28

1558

1558

1558

1555

1554

1558

1537

1541

1545

1508

1516

1526

1463

1481

1497

1405

1435

1459

1336

1380

1415

1256

1316

1362

1167

1244

1302

1068

1162

1232

960

1072

1152

843

973

1059

717

864

926

586

743

751

449

580

571

312

406

391

186

237

218

81

84

68

0

0

0

95 95 95 95

93 93 93 93

88 88 88

85 85 85

81 81 81

80

86 82 79 75

84 80 77 74

77 74 72

74 72 70

71 69 68

66

78 71 65 61

76 70 64 60

67 62 58

64 60 57

62 59 56

54

71 62 55 50

69 61 54 49

58 53 48

56 51 48

54 50 47

45

65 55 47 42

63 54 47 41

51 46 41

50 44 40

48 43 40

38

59 49 41 36

57 48 41 35

46 40 35

44 39 35

43 38 34

33

55 44 36 31

53 43 36 31

41 35 30

40 34 30

39 34 30

28

50 39 32 27

49 39 32 27

37 31 27

36 31 27

35 30 26

25

47 36 29 24

46 35 29 24

34 28 24

33 28 24

32 27 24

22

44 33 26 22

43 32 26 22

31 26 21

31 25 21

30 25 21

20

41 30 24 19

40 30 24 19

29 23 19

28 23 19

28 23 19

18

1238

19.7

24.7

2061

32.7

41.1

3814

60.5

76.0

5016

79.6

100.0

5016

79.6

100.0

L u m i n a n c e Da t a

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

4238

4611

4888

55

4124

4759

5180

65

3890

4933

4986

75

3382

4401

4239

85

2608

2704

2189

S A M P L E N U M B E R : 2 AC - 2 B X 4 0 - 1 2 0 - E B 5 1 - U

Voltage

1

UNV=Universal
120= 120V
277= 277V

Options
GL
=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed

Packaging
U
=Unit Pack

PALC=Job Pack,

in carton

Shielding

Blank=Frosted Acrylic

SQP=Lens with Square

Pattern Insert

RDP=Lens with Round

Pattern Insert

NOTES:

1

Products also available in non-US voltages and frequencies for international markets.

Specifications & dimensions subject to change without notice. Consult your

Ballast Type
EB5
=T5 Biax Electronic Instant Start.

Total Harmonic Distortion < 20%

No. of Ballast

1

Number of Lamps

(Not included)

2=2 Lamp

Wattage (Length)
BX40
=40W Compact
Fluorescent (24")

Series

AC=Accord Series

Width
2
=2' Width

Rating

Blank=

Standard

NY=New York

Rated

ATW-SW4=

Chicago

Rated

Type
A
=Air (optional)

2

For universal voltage, program Rapid Start ballast must be specified.

Cooper Lighting Representative for availability and ordering information.

LB35=Biax lamp, 40W,
3500K
LB41=Biax lamp, 40W,
4100K

(Dedicated voltage required)

2

2AC-2BX40

28 lbs.

Catalog No.

Wt.