HIGH PRESSURE FEED

High pressure makeup water pumps are used when water pressure

does not exceed boiler pressure by more than 10 psi and when con-
densate water is not returned to the boiler. Note: Consult factory or
sales office for motor/pump sizing for appropriate water feed system.

Installation

WARNING: Hazard of Electric Shock. Water feed system
must be effectively grounded in accordance with the
National Electrical Codes to eliminate shock hazard.

1. Locate feed on level floor or platform.
2. Connect water line to tagged fitting on feed.
3. Connect piping from discharge to water inlet check valve on boil-

er with minimum of 90˚ bends or other restrictions.

4. All electrical wiring should be done by licensed electricians in

accordance with local and national electrical codes. Refer to boil-
er instruction for manual wiring diagram.

5. If pump is located less than 30 feet from boiler, a second check

valve is required.

WATER FEED SYSTEMS

Automatic High Pressure Water Feed Pump/Motor Assembly

OPTIONAL EQUIPMENT FOR STEAM BOILERS

16

Pipe

Dimensions (In.)

Assembly

Pressure

Size

Model

HP

Range

(NPT)

A

B

C

D

E

F

ES-38020

3/4

0-200

1/2

16-1/4

3

7-3/16 4-7/8 6-1/2 6-1/8

Pressure

Control

5 Step

Control

Sequencer

Auto

Blowdown

System

Heater Contactor

Heater Contactor

Heater Contactor

Heater Contactor

Feed Water
Solenoid Valve

Boiler
On

Optional Transformer

480/120V

480V 3Ø 60 HZ

CR

W

1

Mtr

Customer

Connect

Feed Water

Motor

10L

30L

20L

IT1

IT3

IT2

CR

L1

L3

L2

Pump Motor Dimensions

Typical wiring for boilers equipped with Auto Blowdown System and/or Solid State Sequencer

Wire Color Code
B

= Black

BR = Brown
R

= Red

O

= Orange

Y

= Yellow

G

= Green

BL = Blue
W = White