Fig. 12—Typical Circuit Connections

WIRING DIAGRAM NOTES FOR DUAL FUEL THERMOSTAT:
1. Underlined letters on dual terminal indicates its usage.

For Example: O/W2 means O

O/W2 means W2

Outdoor Temperature Sensor must be attached in all dual fuel installations.

Jumper wire between O/W2 and L thermostat terminals MUST be present.

2. Y1 and O connections to 2-stage furnaces MAY NOT EXIST, or may only be a wire rather than a screw terminal.

A95215

Y/Y2

W/W1

R

24 VAC HOT

FAN

FURNACE

COMPRESSOR

RVS COOLING

N/A

DUAL FUEL

THERMOSTAT

SINGLE-SPEED

HEAT PUMP

24 VAC COM

RVS HEATING

RVS SENSING

OUTDOOR

SENSOR

CONNECTION

G

R

R

W

Y

Y

G

C

C

O/W2

Y1/W2

SINGLE-STAGE

FURNACE

W2

O

OUTDOOR

TEMPERATURE

SENSOR

SEE NOTE 1

S2

S1

L

B

C

Y/Y2

W/W1

R

24 VAC HOT

FAN

FURNACE LO

COMPRESSOR

RVS COOLING

FURNACE HI

DUAL FUEL

THERMOSTAT

SINGLE-SPEED

HEAT PUMP

24 VAC COM

RVS HEATING

RVS SENSING

OUTDOOR

SENSOR

CONNECTION

S2

S1

L

B

G

R

R

Y

G

C

C

C

O/W2

Y1/W2

TWO-STAGE OR

VARIABLE SPEED

FURNACE

W2

O

SEE NOTES 1 AND 2

W/W1

Y/Y2

O

W2

Y1

OUTDOOR

TEMPERATURE

SENSOR

A95216