beautypg.com

Connect Tech Blue Heat/PCI PCI Serial Communications User Manual

Page 34

background image

Blue Heat/PCI User’s Manual, Connect Tech Inc.

Revision 0.11

34

Example 1

Example 2

The following example shows the
settings on J1 to tri-state the line
drivers upon power up of the Blue
Heat/PCI RS-422/485 adapter (6+2
model). It also shows the settings
on J2 through J13 where the
RS-422/485 port 7 is set for
termination on TxD, RTS and
bias/termination on CTS ±, and
RxD ±; the RS-422/485 port 8 is set
for no bias/termination

The following example shows the
settings on J1 to enable the
RS-422/485 transmitters upon
power up of the Blue Heat/PCI
RS-422/485

adapter (6+2 model).

It also shows the settings on J2
through J13 where the RS-422/485
ports 7and 8 are set for no
termination on TxD, RTS and
bias/termination on CTS ±, and
RxD ±

J1

J2

J3

J4

J5

J6

J7

J8

J9

J10

J11

J12

J13

Legend

J1 = Tri-state control

J2 = TxD termination port 7
J3 = RTS termination port 7
J4 = RxD + bias/termination

port 7

J5 = RxD - bias/termination

port 7

J6 = CTS + bias/termination

port 7

J7 = CTS - bias/termination

port 7

J8 = TxD termination port 8
J9 = RTS termination port 8
J10 = RxD + bias/termination

port 8

J11 = RxD - bias/termination

port 8

J12 = CTS + bias/termination

port 8

J13 = CTS - bias/termination

port 8

J1

J2

J3

J4

J5

J6

J7

J8

J9

J10

J11

J12

J13

Legend

J1 = Tri-state control

J2 = TxD termination port 7
J3 = RTS termination port 7
J4 = RxD + bias/termination

port 7

J5 = RxD - bias/termination

port 7

J6 = CTS + bias/termination

port 7

J7 = CTS - bias/termination

port 7

J8 = TxD termination port 8
J9 = RTS termination port 8
J10 = RxD + bias/termination

port 8

J11 = RxD - bias/termination

port 8

J12 = CTS + bias/termination

port 8

J13 = CTS - bias/termination

port 8

Note:
If you wish to bias/terminate CTS ± on a specific port, you must
jumper both CTS ± positions on the appropriate jumper block.

If you wish to bias/terminate RxD ± on a specific port, you must
jumper both RxD ± positions on the appropriate jumper block.