beautypg.com

Appendix a: specifications, Operating environment, Power requirements – Connect Tech Blue Heat/PCI PCI Serial Communications User Manual

Page 17

background image

Blue Heat/PCI User’s Manual, Connect Tech Inc.


17

Revision

0.11

Appendix A: Specifications

Operating Environment

„

Storage

temperature:

-65

° C - 150° C

„

Operating

temperature:

0

° C to 70° C

„

Relative humidity: 5 - 95% non-condensing

„

Air movement:

no requirement

„

Altitude: 15,000 feet (5000 metres)

Power Requirements

„

Blue Heat/PCI (2 port model)

+5 VDC +/-5% @ 200 mA (typical
+/-12VDC +/-10% @ 20 mA (typical)

„

Blue Heat/PCI (4 port model)

+5 VDC +/-5% @ 220 mA (typical)
+/-12VDC +/-10% @ 60 mA (typical)

„

Blue Heat/PCI (8 port model)

+5 VDC +/-5% @ 320 mA (typical)
+/-12VDC +/-10% @ 120 mA (typical)

„

Blue Heat/PCI RS-422/485 (8 port model)

+5 VDC

±5% @ 600mA

„

Blue Heat/PCI RS-422/485 (6+2 model)

+5 VDC

±5% @ 500mA

„

Blue Heat/PCI RS-422/485 (4+4 model)

+5 VDC

±5% @ 550mA

„

Blue Heat/PCI RS-422/485 (4 port model)

+5 VDC

±5% @ 400mA

„

Blue Heat/PCI RS-422/485 (2+2 model)

+5 VDC

± 5% @ 350mA

„

Blue Heat/PCI RS-422/485 (2 port model)

+5 VDC

±5% @ 300mA

„

Blue Heat/PCI RJ-11

+5 VDC

±5% @ 400mA (typical)

±12 VDC ±10% @ 144mA (typical)

„

Blue Heat/PCI Opto; /PCI Opto RS-422/485 (2 port models)

+5 VDC

±5% @ 320mA (typical)

„

Blue Heat/PCI Opto; /PCI Opto RS-422/485 (4 port models)

+5 VDC

±5% @ 500mA (typical)

„

Blue Heat/PCI CL

+5 VDC

±5% @ 375mA (typical)

±12 VDC +/-10% 320mA (max.)

„

Universal Blue Heat/PCI RS-422/485 (4+4 model)

+3 VDC

±5% @ 100mA (typical)

+5 VDC