beautypg.com

Operation – Desa Tech CRL3124PA/NA User Manual

Page 20

background image

www.desatech.com

113097-01L

20

5. Slightly press and turn control knob coun-

terclockwise

to the PILOT position.

Press in control knob for five (5) seconds
(see Figure 29).

Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.

6. With control knob pressed in, press and

release ignitor button. This will light pilot.
The pilot is attached to the burner. If
needed, keep pressing ignitor button until
pilot lights.

Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.

7. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob.

Note: If pilot goes out, repeat steps 3
through 7. If control knob does not pop out
when released, contact a qualified service
person or gas supplier for repairs.

8. Slightly depress and turn control knob

counterclockwise

to desired heat-

ing level. The burner(s) should light. Set
control knob to any heat level between HI
and LO.

9. To leave pilot lit and shut off burners only,

turn control knob clockwise

to the

HI position then press in and turn clock-
wise

to PILOT position.

WARNING: Do not operate

heater between PILOT and HI

positions.

OPERATION

Continued

MANUALLy-CONTROLLED MODELS

Figure 29 - Control Knob and Ignitor

Button Location

Ignitor Button

Control Knob

Figure 30 - Pilot

Thermocouple

Pilot Burner

Ignitor
Electrode

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any
heat setting and flame height desired, by sim-
ply turning the control knob until that setting
is attained. Even the lowest setting provides
realistic, dancing yellow flames. Selecting
higher settings produces greater heat output.
This results in increased heating comfort.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

1. Press in and turn control knob clockwise

to the HI position.

2. Turn control knob clockwise

to the

pilot position.

3. Press in control knob and turn clockwise

to the OFF position.

4. Close equipment shutoff valve (see Figure

16, page 15).

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions, pages 19 and 20.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8,
under Lighting Instructions, column 1.