beautypg.com

Installation – Desa Tech CRL3124PA/NA User Manual

Page 13

background image

www.desatech.com

113097-01L

13

INSTALLATION

Continued

IMPORTANT: Make sure the heater burners
are level. If heater is not level, heater will not
work properly. For thermostat models, avoid
damage to thermostat bulb. Avoid nicks or
sharp bends in thermostat bulb wire. Keep
thermostat bulb in mounting bracket until
ready to mount base to floor. See Optional
Positioning Of Thermostat Sensing Bulb
,
page 29.

Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided)

(if allowed by local codes)

• sealant resistant to propane (propane/LP)

gas, not provided

• electric drill with 3/16" drill bit
• flathead screwdriver
1. Apply pipe joint sealant lightly to male

threads of the fitting to be threaded into
gas regulator. Connect approved flexible
gas hose to gas regulator of heater (see
Figure 11).

IMPORTANT: Hold gas regulator with
wrench when connecting flexible gas hose.

2. Locate masonry screws in hardware

package.

3. Position heater base assembly in fireplace.
4. Place logs in their proper position on heater

base, see Installing Logs on page 16.

5. Center heater base and logs front-to-back

and side-to-side in fireplace.

6. Carefully remove logs without moving

heater base.

7. Mark screw locations through holes in

mounting brackets (see Figure 12 and
13). If installing in a brick-bottom fireplace,
mark screw locations in mortar joint of
bricks.

8. Remove heater base from fireplace.

9. Drill holes at marked locations using 3/16"

drill bit.

10. Attach base assembly to fireplace floor

using two masonry screws (in hardware
package) (see Figure 12 or 13).

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

Figure 12 - Attaching Base Assembly to

Fireplace Floor - Dual Burner Model

Heater Gas
Regulator

Flexible Gas Hose
(if allowed by local codes)

Fitting

Masonry
Screw

Mounting
Bracket

Masonry
Screw

Figure 13 - Attaching Base Assembly to

Fireplace Floor - Single Burner Model

Mounting
Bracket

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified ser-

vice person must connect heater

to gas supply. Follow all local

codes.