beautypg.com

Dell PowerVault 110T SDLT320 (Tape Drive) User Manual

Page 23

background image

Back to Contents Page

Regulatory Compliance: Dell

™ PowerVault™ 110T SDLT 320 Tape Drive User's Guide

• 

Safety Regulations

• 

Electromagnetic Field Specifications

• 

Acoustic

Safety Regulations

This section lists the safety regulations that the PowerVault 110T tape system meets or exceeds, such as UL, CSA, EN/IEC, and

“GS” Mark.

Safety Certifications

The SDLT tape system meets or exceeds requirements for safety in the United States (UL 1950), Canada (CSA950 C22.2 No. 950) and Europe (EN60950/IEC 950), and is
certified to bear the GS mark.

Safety Requirements

Safety requirements include:

UL1950: Information Technology Including Electrical Business Equipment

CSA950 C22.2 No. 950: Information Technology Including Electrical Business Equipment

EN60950/IEC 950: Information Technology Including Electrical Business Equipment

Electromagnetic Field Specifications

Electromagnetic Emissions

Once the internal tape drive is mounted into an enclosure and grounded, the internal drive complies with FCC Class A; the external tape drive complies with the FCC Class B
limits.

Conducted Emissions

Limits for Class B equipment are in the frequency range from 0.15 to 30 MHz.

Table 1. Conducted Emissions

Radiated Emissions

Limits of radiated interference field strength, in the frequency range from 30 MHz to 1000 MHz at a test distance of 10 meters, are listed in Table 2.

Table 2. Radiated Emissions

Susceptibility and ESD Limits

Table 3 and Table 4 list radiated, magnetic radiated, and conducted susceptibility and ESD failure level limits for the tape drive.

Table 3. Radiated, Magnetic Radiated, and Conducted Susceptibility

Frequency Range

Limits dB

 

Quasi-peak

Average

0.15 to 0.50 MHz

66 to 56*

56 to 46

0.50 to 5 MHz

56

46

5 to 30 MHz

60

50

* The limit decreases linearly with the logarithm of the frequency.

Frequency Range

Quasi-peak limits dB (

µV/m)

 

Class A

Class B

30 to 230 MHz

40

30

230 to 1000 MHz

46

37

Above 1000 MHz

54

Not applicable

Type

Specifications

Comments

Radiated Immunity - High Frequency, Electric Fields

3 V/m (rms), 80% modulated, 1 KHz, 26 to 1000 MHz

No errors*
No screen distortion

Magnetic Radiated - Low Frequency, Magnetic Fields

3 A/m @ 230V/50 Hz

No errors*
No screen distortion

EFT- Fast Transient (Bursts) for Power and Data Cables

2 kV

No errors*

PLT- High Energy Transient Voltage for Power Cables

1.2 kV (Differential) 2.5 kV (Common mode)

No errors*

Low-

Level Conducted ‡ Interference for AC and DC Cables

3 V/m (rms), 80% modulated, 1 kHz,
0.15 - 80 MHz

No errors*
No screen distortion