Dell PowerVault 110T SDLT320 (Tape Drive) User Manual
Page 21

Back to Contents Page
Jumpers: Dell
™ PowerVault™ 110T SDLT 320 Tape Drive User's Guide
so on the back of the Dell PowerVault 110T SDLT 320 tape drive. The table below shows the same information, but in a tabular form. For your convenience,
shows
the location of the SCSI ID jumper block on an internal drive.
To change the SCSI ID of an external tape drive, use a different approach. The external tape drive has a SCSI ID selector block that you manipulate with a slender object such
as a screwdriver or a ball-point pen. For details, see
Setup:Installing External Drives
.
Figure 1. Setting SCSI ID: Jumper Placement
Table 1. Placing Jumpers to Select the SCSI ID
Figure 2. Necessary Jumpers on the SCSI ID and TERMPWR Blocks (on Back of Internal Drive)
SCSI ID
0
1
2
3
Jumper Block
SCSI ID
4
5
6 (default)
7
Jumper Block
SCSI ID
8
9
10
11
Jumper Block
SCSI ID
12
13
14
15
Jumper Block
SCSI ID
Jumper Across Pins
9-10
7-8
5-6
3-4
1-2
0
1
0
0
0
0
1
1
0
0
0
1
2
1
0
0
1
0
3
1
0
0
1
1
4
1
0
1
0
0
5
0
0
0
0
1
6 (default)
1
0
1
1
0
7
1
0
1
1
1
8
1
1
0
0
0
9
1
1
0
0
1
10
1
1
0
1
0
11
1
1
0
1
1
12
1
1
1
0
0
13
1
1
1
0
1
14
1
1
1
1
0
15
1
1
1
1
1
0=No jumper installed
1 = Jumper installed