Method 2 (discovery using isns server) – Dell PowerVault NX1950 User Manual
Page 24

24
Quick Install Steps for Initiator-Target Connection
5 In the Log On to Target window, click OK.
The
Targets tab displays the status of the Target as Connected.
6 To accomplish Multipathing, you can use Microsoft MPIO to establish
multiple sessions from host to the same Target device. To establish
multiple sessions:
a
Go to the Targets tab and select the Target that is Connected.
b
Repeat step 1 to step 4.
c
In the Advanced Settings→ Target Portal address, choose the redundant
host IP address and the IP address of the PowerVault NX1950 storage
solution.
NOTE:
During the iSCSI Initiator software installation, Microsoft MPIO is
already selected. MPIO is supported with Initiator version of 2.06 or later. You
require two dedicated iSCSI NICs in the target and initiator for efficient MPIO
connection. Multiple connections per session (MC/S) is not supported on the
PowerVault NX1950 storage solution.
7 To initialize and configure the iSCSI device as local drive and perform iSCSI
I/O operations, select
Computer Management→ Disk Management option.
NOTICE:
If you are configuring the host to access multiple targets (VHD files),
ensure that the hosts are clustered. If multiple hosts access the same target, data
corruption may occur. For more information, see "Enabling Multi-Path on the
Method 2 (Discovery Using iSNS Server)
This section describes the procedure for iSCSI Target discovery using the
iSNS server. For more information about the iSNS server, see "Appendix" on