beautypg.com

Important information – Dell PowerVault 220S (SCSI) User Manual

Page 12

background image

12

Updating the Enclosure Management Module Firmware

www

.dell.com | support.dell.com

FILE LOCATION: S:\systems\Zappa\Ts\EMM Firmware_N8865\N8865eb0.fm

DELL CONFIDENTIAL – PRELIMINARY 10/26/04 – FOR PROOF ONLY

5

Download the pv22xLxx.gz utility file from the Dell Support website at support.dell.com and
save the utility to the directory you created in step 3.

6

Uncompress the .gz file.

For example, in the command prompt, type the following and then press :

tar -zxvf pv22xL

xx.gz

Included in the extracted files are an .exe utility file and a .bin firmware file.

7

Change the file permissions for the extracted .exe file.

In the command prompt, type the following and then press :

chmod +x pv22xL

8

Run the utility.

In the command prompt, type the following and then press :

./pv22xL -i

9

Record the listed file descriptor of the enclosure you wish to update. An example descriptor
could be /dev/sg8.

10

In the command prompt, type the following and then press :

./pv22xL -x <

file_name> -d

Where is the full path name to the location of the firmware .bin file and
is the device you are updating.

For example:

./pv22xL -x pv22xs_E17.bin -d /dev/sg8

When the update completes, a message appears indicating that the update was successful.

11

Restart I/O activity to the storage system.

Important Information

Updating the Storage System in Joined Bus or Cluster Mode

When the split-bus module is in the joined-bus mode (default) or cluster mode, the EMM
firmware is downloaded to both EMMs automatically (assuming that the second EMM is
installed).

This manual is related to the following products: