beautypg.com

System messages, Table 2 – Dell PowerEdge 1600SC User Manual

Page 28

background image

 

 

Table 2-6. NIC Indicator Codes 

 

System Messages

 

System messages alert you to a possible operating system problem or to a conflict between the software and hardware.

Table 2

-7

lists the system error

messages that can occur and the probable cause for each message.

 

 

 

Table 2-7. System Messages 

Indicator

Indicator Code

 

Link and activity indicators are off.  The NIC is not connected to the network.

 

Link indicator is green.

 

The NIC is connected to a valid link partner on the network.

 

Activity indicator is amber blinking.  Network data is being sent or received.

NOTE:

If you receive a system message that is not listed in

Table 2

-7

, see the documentation for the application that is running when the message

appears and/or the operating system documentation for an explanation of the message and recommended action.

Message

Causes

Corrective Actions

 

Address mark not found

 

Faulty CD drive, diskette drive, or hard-drive; faulty

system board.

 

See "

Troubleshooting the Diskette Drive

," "

Troubleshooting a CD

Drive

," and "

Troubleshooting Hard Drives

" in "Troubleshooting Your

System."

 

Alert! Back system fan was

not detected.

 

Specified fan is missing, faulty, or improperly

installed.

 

See "

Troubleshooting System Cooling

" in "Troubleshooting Your

System."

 

Alert! CPU n fan was not

detected.

 

Alert! Front system fan was

not detected.

 

Alert! Cover was previously

removed!

 

The chassis has been opened.

 

Information only.

 

Alert! Previous back system

fan failure.

 

Specified fan failed before last system startup (see

Figure 5

-5

to identify the fans).

 

Information only.

 

Alert! Previous CPU n fan

failure.

 

Alert! Previous front system

fan failure.

 

Alert! Previous voltage

failure.

 

Power supply failed before last system startup.

 

Information only.

 

Alert! Processor thermal

probe failure detected.

 

Microprocessor fan is missing, faulty, or improperly

installed.

 

See "

Troubleshooting System Cooling

" in "Troubleshooting Your

System."

 

Alert! Unsupported memory or

incomplete sets in the

 

Faulty memory module(s).

 

Ensure that all memory modules are properly installed. If the

problem persists, see "

Troubleshooting System Memory

" in

"Troubleshooting Your System."