Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing door or gate.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the other

control may also need adjustment.

• After ANY adjustments are made, the safety reversal system

MUST be tested. Door MUST reverse on contact with 38 mm
obstacle on the floor. Gate MUST reverse on contact with
38 mm obstacle at the closing edge.

ADJUSTMENT STEP 3

Test the Safety Reversal System

Garage Door Installation

TEST

With the door fully open, place a 38 mm obstacle on the
floor, centered under the garage door.

Operate the door in the down direction. The door must
reverse on striking the obstruction.

ADJUST

If the door stops on the obstruction, it is not traveling far
enough in the down direction. Increase the DOWN limit by
turning the DOWN limit adjustment screw counterclockwise
1/4 turn.

NOTE: On a sectional door, make sure limit adjustments

do not force the door arm beyond a straight up and down
position. See the illustration on page 27.

Repeat the test.

When the door reverses on the 38 mm obstacle, remove
the obstruction and run the opener through 3 or 4 complete
travel cycles to test adjustment.

IMPORTANT SAFETY CHECK:

Repeat Adjustment Steps 1, 2 and 3 after:

Each adjustment of door arm length, limits, or force
controls.

Any repair to or adjustment of the garage door (including
springs and hardware).

Any repair to or buckling of the garage floor.

Any repair to or adjustment of the opener.

Gate Installation

TEST

The opener must reverse if the gate comes in contact with an
obstruction. A closing gate should reverse with little effort,
and open completely. See Adjustment Step 2.

Use 38 mm board laid flat against the wall or gate edge.

SLIDING GATE DOOR, place a 38 mm board between the

door and wall of a closing gate. Gate must reverse on the
board and open completely. Repeat at opposite wall if two
openers are installed.

SWING OUT GATE, insert a 38 mm board between the

closing gate sections. Gate sections must reverse and
swing open completely.

ADJUST

If the gate stops on the obstruction, it is not traveling far
enough in the closing direction. Increase the DOWN limit
adjustment screw counterclockwise 1/4 turn. Repeat test.

When the gate reverses on a 38 mm board, remove the

obstruction and run the opener through complete travel
cycle to test adjustment.

If the gate will not reverse after repeated adjustment
attempts, call for professional gate service.

ONE-PIECE DOOR

SECTIONAL DOOR

38 mm Obstacle

38 mm Obstacle

38 mm Obstacle

38 mm
Obstacle

SWINGING GATE