NVB Series B-Vent Gas Fireplace

7412950

LG148

NVB42

log set

1/30/01 djt

Left Rear

Log

Left Cross

Log

Middle Cross

Log

Right Cross

Log

Right Rear

Log

Ember

Left Log

Embers

Grate

Lava Rock

Ember

Right

Fig. 16 NVB42 log placement.

LG148

Under no circumstances should lava rock
be placed on any part of the burner assem-
bly.

First Firing

Upon completing the gas line connection, a small
amount of air will be trapped in the line. When first
lighting the unit with pilot light, it will take a few minutes
to purge the trapped air. Once purging is complete, the
pilot and burner will light and operate as indicated in the
instruction manual. Subsequent lightings of the appli-
ance will not require purging.
When lit for the first time, the appliance will emit a slight
odor for an hour or two. This is due to paint and lubri-
cants used in the manufacturing process. After each
lighting, vapor may condense and fog the glass; this
moisture disappears in a few minutes of burning.

Flame Adjustment

For units equipped with Hi/Lo valves, flame adjustment
is accomplished by rotating the Hi/Lo adjustment knob
located near the center of the gas control.

Flame Characteristics

It is important to periodically perform a visual
check of the pilot and the burner flames.
Compare them to the illustrations below
(Figs. 18, 19, 20). If any of the flames ap-
pear abnormal call a service person.

Inspecting the Venting System

The appliance venting system was designed
and constructed to develop a positive flow
adequate to remove flue gases to the out-
side atmosphere.
Any foreign objects in the venting system,
except those designed specifically for the
venting system, may cause spillage of flue
gases (i.e.: carbon monoxide) into the room.
To inspect the venting system, make sure
the main gas valve is off. Remove the glass
panel. Using a flashlight, check the combus-
tion dome and behind the top grille. Clean if
necessary.

LO

HI

Turn

counterclockwise

to increase

flame height

Turn clockwise

to lower

flame height

FP390

FLAME ADJUSTMENT KNOB

11/21/96

Fig. 17 Flame adjustment knob for SIT820 valve.

Fig. 18 Proper pilot flame height.

FP581

3/8"-1/2"

FP581

NVB-PILOTS

12/4/97

NOVA SIT PILOT

ELECTRONIC

IGNITION

This manual is related to the following products: