Nvb series b-vent gas fireplace, Venting runs – Vermont Casting NVBR36 User Manual

Page 11

background image

11

NVB Series B-Vent Gas Fireplace

7412950

FP567

Fig. 13 Venting configurations.

�����
����������������������
��������

Venting Runs

��
��
��
��
��
��
��
��
��
��
��
��
��
��
��

������������

��������������������������������

Horizontal Run (in feet)

Vertical Run (in feet)

A

A: Vertical installations up to 40 feet (12m) in

height. Up to a 6 ft. horizontal vent run can be

installed within the vent system using a

maximum of two 90-degree elbows or four

45-degree elbows.

B: Vertical installations up to 40 feet (12m) in

height. Up to a 10 ft. horizontal vent run can be

installed within the vent system using a

maximum of two 45-degree elbows.

B

= Acceptable venting configuration
= Unacceptable venting configuration

FP567a

Fig. 14 Venting configurations when installing 36GSKBB.

40
38
36
34
32
30
28

26
24

22

20

18

16
14

12

10

8

2

4 6

8 10 12 14 16 18 20

A

FP567a

Venting Run

Graph

8/17/99 djt

Horizontal Run (in feet)

Vertical Run (in feet)

= Acceptable venting configuration

= Unacceptable venting configuration

A: Vertical installation up to 40 feet (12m) in

height. Up to a 16 ft. horizontal vent run

can be installed within the vent system

using a maximum of two 90 degree elbows

or four 45 degree elbows.

B: Vertical installation up to 40 feet (12m) in

height. Up to a 20 ft. horizontal vent run

can be installed within the vent system

using a maximum of two 45 degree elbows.

B