libraryTapeAlert15 NOTIFICATION-TYPE
OBJECTS {
faultyLibLocation,
librarySerialNumber
}
STATUS current
DESCRIPTION "Notification that the library set Tape Alert 15,
indicating a problem when loading a drive."
--#TYPE "Drive load problem"
--#SUMMARY "A drive load problem occurred at drive %s in
library %s."
--#ARGUMENTS {0,1}
--#SEVERITY CRITICAL
::= { tapeLibraryMIBNotifications 135 }
libraryTapeAlert16 NOTIFICATION-TYPE
OBJECTS {
librarySerialNumber
}
STATUS current
DESCRIPTION "Notification that the library set Tape Alert 16,
indicating an open library access door."
--#TYPE "Library main access door open"
--#SUMMARY "A main access door is open in library %s."
--#ARGUMENTS {0}
--#SEVERITY CRITICAL
::= { tapeLibraryMIBNotifications 136 }
libraryTapeAlert17 NOTIFICATION-TYPE
OBJECTS {
faultyLibLocation,
librarySerialNumber
}
STATUS current
DESCRIPTION "Notification that the library set Tape Alert 17,
indicating a mailbox station mechanical problem."
--#TYPE "Mailbox mechanical problem"
--#SUMMARY "A mechanical mailbox problem occurred at
location %s of library %s."