beautypg.com

Dell PowerVault 124T User Manual

Page 55

background image

l

Verify that the autoloader operates correctly when properly configured and attached directly to a host
system using a cross-over cable.

l

If all previous steps fail, see

Contacting Dell

.

Error

52

IP Stack Can't Free Memory

53

Stack DTrap Occurred

Loader Task Error Types

60

Drive Init Failed

l

Check

support.dell.com

for PowerVault 124T firmware updates.

l

Check the TapeAlert log for more specific drive error information. Refer to

Table 3

for recommended

actions.

l

Power cycle the autoloader using the front panel power button and retry the operation.

l

If all previous steps fail, see

Contacting Dell

.

61

Drive Login Error

62

Drive Logout/Unexpected Error

63

Drive Command Failed

64

Drive Response Timeout

65

Command Flushed From Queue

66

Drive Manager Not In Correct
State

67

Drive Reporting Not Ready

68

Autoclean Move Failed

l

Check the Remote Management Unit autoclean Configuration settings. Insure that a valid cleaning
cartridge is located at the configured location.

l

Verify that the cleaning cartridge does not have labels or other matter placed anywhere on the
cartridge except where labels are expected to be placed.

l

Try a different cleaning cartridge.

l

If the operation fails with two different cleaning cartridges, see

Contacting Dell

.

69

Drive Unload Retry

l

Check the TapeAlert log for more specific drive error information. Refer to

Table 3

for recommended

actions.

l

Verify that the cleaning cartridge does not have labels or other matter placed anywhere on the
cartridge except where labels are expected to be placed.

l

Try to load a different piece of media.

l

Power cycle the autoloader using the front panel power button and retry the operation.

l

If all previous steps fail, see

Contacting Dell

.

6D

Drive Communications Error

l

Check

support.dell.com

for PowerVault 124T firmware updates.

l

Check the TapeAlert log for more specific drive error information. Refer to

Table 3

for recommended

actions.

l

Power cycle the autoloader using the front panel power button and retry the operation.

l

If all previous steps fail, see

Contacting Dell

.

6E

Drive Communications Error

6F

Loader Communication Error

Code Update Error Types

70

Failed to Send CUP Cmd to
Drive / No Response From Drive

l

Verify the firmware images for both the autoloader and drive are the most recent images located at

support.dell.com

.

l

Review the firmware update readme file provided with the firmware images.

Note: The recommended method for drive firmware update is through the host interface using the
DFU utility provided with the firmware images. The recommended method for loader firmware update
is through the Remote Management Unit.

l

Verify all SAS cable connections between the host and autoloader.

l

Verify no media in drive during update.

l

Power cycle the autoloader using the front panel power button and retry the operation.

l

If all previous steps fail, see

Contacting Dell

.

71

CUP Send Failed

72

Drive Update Failed, Media
Present

73

Image Size in Header Too Big

74

Block Erase Failed

75

Flash Program Failed

76

Header Corrupt

77

Checksum Error

78

Timeout During CUP

79

Reset During Drive Update

7A

Unexpected Reset From Drive

7B

Unexpected Message From PSP

7C

Personality or Version Check
Failed

7D

Error During Write Buffer
Command

7E

Uncompressed EDC Failure

7F

Image Processing Ended Early

Server Task Error Types

80

Unexpected Response or Data
Received

l

Verify the host backup application and device driver are at the latest supported revision at

support.dell.com

.