beautypg.com

Dell PowerVault NX3300 User Manual

Page 7

background image

• Enter the PERC BIOS during the operating system boot operation and ensure

that there are no foreign configurations, no data on the drives, the drives meet

the minimum size requirement, and are fully functioning and accessible.
For more information, see the PERC documentation at dell.com/support/
manuals.

Error: -5005 Occurred While Creating An Operating

System Volume

Description

Drives in expected operating system slots have existing foreign configurations.

Workaround

To work around this issue, enter the PERC BIOS during the operating system boot
operation and ensure that there are no foreign configurations, no data on the
drives, the drives meet the minimum size requirement, and are fully functioning
and accessible.
For more information, see the PERC documentation at dell.com/support/manuals.

Error: -5006 Occurred While Creating An Operating

System Volume

Description

Unable to locate the PowerVault operating system reinstallation media.

Workaround

To work around this issue, perform one of the following steps:

• Ensure that the operating system reinstallation media is loaded in the optical

drive. If the media is present in the drive, the drive may be faulty.
For information about troubleshooting the drive, see the Owner’s Manual at
dell.com/support/manuals.

• Ensure that the drive is still functional. Reboot the PowerVault NAS using the

operating system reinstallation media to restart the process.

Error: -5007 Occurred While Creating An Operating

System Volume

Description

A pre-existing virtual disk with LUN ID 0 that is not being used for the NAS
operating system has been encountered. The operating system on the PowerVault
NAS system must be on virtual disk 0.

Workaround

To work around this issue, delete the current virtual disk with LUN ID 0 for the
operating system reinstallation to proceed.

1.

Backup all data on virtual disk 0 if possible.

2.

Reboot your system and boot into the PERC controller BIOS during Power On

Self Test (POST).
For more information about booting into the PERC controller BIOS, see the
PERC User’s Guide at dell.com/support/manuals.

3.

Delete the virtual disk with LUN ID 0.