If the iSCSI initiators are connected to MD3200i and/or

MD3600i series through the network switches, make

sure that your switches support IEEE 802.3x flow

control, and the flow control is enabled for both

sending and receiving on all switch ports and server

NIC ports.

If you do not enable the flow control, your iSCSI

storage array may experience the degradation of the
I/O performance.

In addition to enabling the Ethernet IEEE 802.3x flow
control it is also recommended to disable unicast
broadcast storm control on the switch ports connected
to the iSCSI initiators and target arrays and turn on the
"PortFast" mode of the spanning tree protocol (STP) on
the switch ports connected to the iSCSI initiators and
target arrays.

Note that turning on the "PortFast" mode is different
from turning off the whole operation of STP on the
switch. With "PortFast" on, the STP is still enabled on
the switch ports. Turning STP off may affect the entire
network and can leave the network vulnerable to
physical topology loops.

N/A

N/A

For optimal I/O performance, avoid having more than

one iSCSI session originating from one host iSCSI port

to the same controller. Ideally, the iSCSI host NIC

should be connected to only one iSCSI target port on

the storage subsystem.

N/A

N/A

For Dell-Oracle Tested and Validated solutions on the

MD arrays, please refer to the following site <

http://en.community.dell.com/techcenter/enterprise-

solutions/w/oracle_solutions/current-release.aspx

>

The number of VD copies limited to a maximum of 511

with a maximum of 8 concurrent copies (applicable to

RAID controller firmware version 07.84.xx.xx)

Remote Replication is not supported in Simplex Mode.

N/A

Maximum number of iSCSI sessions.

N/A

192 per port 448 per port

N/A