beautypg.com

Dell powervault md-series storage array rules – Dell PowerVault MD3260 User Manual

Page 6

background image

6

Dell PowerVault MD-Series Storage Array Rules

This section contains both general and model-specific connectivity and consideration rules
for MD storage arrays. Only the rules shown in

Table 2

apply to ALL storage array models. For

rules applying to specific MD models, see

Tables 3 and 4

.

Table 2. MD-Series Storage Array Rules for All Models

NOTE: MD3260, MD3260i, MD3660i and MD3660f platforms are

supported in dual-RAID controller (duplex) configurations only.

MD3200

series

MD3200i

series

MD3600i

series

MD3600f

series

RULE

6Gbps

SAS

1Gbps

iSCSI

10Gbps

iSCSI

8Gbps

Fibre

Channel

Maximum number of host servers a single storage array

can connect to with one RAID controller module

installed

4

32

64

64

Maximum number of host servers a single storage array

can connect to with two RAID controller modules

installed

8

(4 if using

high

availability)

32

64

64

Maximum number of Dell 6GbSAS HBA cards supported

in a single host server attached to single array. (It is

recommended to use two Dell 6Gb SAS HBA cards for

all redundant cabling configurations.)

2

(each card

has two

ports)

N/A

N/A

N/A

Unused ports on a Dell 6Gb SAS HBA card already

connected to an MD3260 cannot be connected to

another device (such as a tape drive or other model

storage array).

N/A

N/A

N/A

Maximum number of MD Series Storage Arrays a host

server may connect to:

2 (HA)

4

4

4

SAS and iSCSI storage arrays can be connected to the
same host server.

The I/O co-
existence
between the
Fibre Channel
and any other
protocol on
same host is
not
supported.