Dell POWERVAULT MD3620F User Manual
Page 16
16
Hardware Installation
a
Stop all I/O to the storage array and turn off affected host systems
attached to the storage array.
b
Turn off the storage array.
c
Turn off any expansion enclosure(s) in the affected system.
3 Cable the expansion enclosure(s) to the storage array.
4 Turn on attached units:
a
Turn on the expansion enclosure(s). Wait for the enclosure status
LED to turn blue.
b
Turn on the storage array and wait for the status LED to indicate that
the unit is ready:
• If the status LEDs are solid amber, the storage array is still coming
online.
• If the status LEDs are blinking amber, there is an error that can be
viewed using PowerVault MDSM.
• If the status LEDs are solid blue, the storage array is ready.
c
After the storage array is online and ready, turn on any attached host
systems.
5 Using PowerVault MDSM, update all attached expansion enclosure
firmware if it is out of date:
a
From the EMW, select the enclosure that you want to update and
enter the
Array Management Window (AMW).
b
Click AdvancedMaintanence DownloadEMM Firmware.
c
Select Select All to update all the attached expansion enclosures
simultaneously.
book.book Page 16 Friday, September 9, 2011 11:26 PM