NIC Teaming Limitations

If you configure the baseboard management controller (BMC) to access the system using the first
integrated NIC (NIC1), teaming functionality and BMC functionality are affected in certain
situations, as shown in Table 1-2.

NOTE:

To avoid false error messages, use only the Intel

®

NIC drivers provided by Dell.

Table 1-2.

Effect of BMC Use of NIC1 on Teaming Functionality

AFT, ALB/RLB, and SFT
Teaming Mode

IEEE 802.3ad and Ether Channel
Teaming Mode

Action

Effect

Effect

NIC1 allocated to BMC
before team is created

Normal teaming and BMC
functionality.

BMC and NIC1 issue a warning
message about the loss of
management traffic in the event
of adaptive failover.

Normal teaming functionality.
BMC functionality may be
affected because of loss of
management traffic.

BMC and NIC1 issue a warning
message about loss of
management traffic in the event
of adaptive failover.

NIC1 allocated to BMC
after team is created

Normal teaming and BMC
functionality.

BMC issues a warning message
about the loss of management
traffic in the event of adaptive
failover.

NIC1 does not display a warning
message but teaming functions
normally.

Normal teaming functionality.
BMC functionality may be
affected because of loss of
management traffic.

BMC issues a warning message
about loss of management traffic
in the event of adaptive failover.

NIC1 does not display a warning
message but teaming functions
normally.

NIC1 BMC access disabled
before team is created

Normal teaming functionality

Normal teaming functionality

NIC1 BMC access disabled
after team is created

Normal teaming functionality

Normal teaming functionality