Dell PowerEdge 2850 User Manual
Page 11
![background image](/manuals/609096/11/background.png)
Information Update
9
E0D76
BP DRIVE n
1x2 DRIVE FAIL n
SCSI CONNECTOR
Faulty or improperly installed
hard drive or RAID controller.
See "Troubleshooting SCSI Hard
Drives" "Troubleshooting a RAID
Controller Card, " and
"Troubleshooting the Integrated
RAID Controller" in your
Installation and Troubleshooting
Guide.
EB107
PROC BUS ERR
PROC INIT ERR
PROC PROTOCOL
ERR
Faulty or improperly installed
microprocessor or system board.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide. If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
EB107
PCIE FATAL ERR
CHIPSET ERR
Faulty or improperly installed
PCI-e card.
Faulty or improperly installed
riser card.
Faulty system board.
Remove and reseat the PCI-e
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" in your
Installation and Troubleshooting
Guide.
Reinstall the expansion-card cage.
See "Installing the Expansion-
Card Cage" in your Installation
and Troubleshooting Guide.
If the problem persists, the riser
card or system board is faulty.
See "Getting Help" in your
Installation and Troubleshooting
Guide.
EB107
MEMORY MIRRORED
Memory mirroring enabled.
Information only.
EB107
MEMORY SPARED
Memory spare bank enabled.
Information only.
EFFF2
ROMB PRESENCE
Integrated RAID controller is
activated.
Information only.
IB110
SBE LOG DISABLED
LOGGING DISABLED
Information only.
IS000
INTRUSION
System cover has been removed.
Information only
NOTE:
For the full name of an abbreviation or acronym used in this table, see the "Glossary"
in your User’s Guide.
Table 1-4.
LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions