beautypg.com

Serial communication screen, Operating system information, Enumeration of nics – Dell PowerEdge 2900 User Manual

Page 22

background image

22

Information Update

Serial Communication Screen

Table 1-7 lists the updated information on the default Failsafe Baud Rate.

Operating System Information

Enumeration of NICs

Linux operating system versions that use the udev kernel device manager
enumerate the NICs differently than earlier Linux versions that used the
devfs device manager. Although this does not affect system functionality,
when using Red Hat

®

Enterprise Linux

®

(version 4 or version 5) or SUSE

®

Linux Enterprise Server 9 or 10 operating systems, the NICs are enumerated
in reverse: NIC1 is configured as eth1 instead of eth0, and NIC2 is configured
as eth0 instead of eth1. For information on how to change the default device
enumerations, see the “Network Interface Card Naming” white paper
available at linux.dell.com.

TPM Clear
(No default)

NOTICE:

Clearing the TPM causes loss of all

encryption keys in the TPM. This prevents booting to
the operating system and results in loss of data if the
encryption keys cannot be restored. Be sure to back
up the TPM keys prior to enabling this option.

When set to Yes, all the contents of the TPM are cleared.

NOTE:

This field is read-only when

TPM Security is set

to

Off.

Table 1-7.

Serial Communication Screen Option

Option Description

Failsafe Baud Rate

(115200 default)

Displays the failsafe baud rate used for console redirection
when the baud rate cannot be negotiated automatically
with the remote terminal. This rate should not be adjusted.

Table 1-6.

New System Security Screen Options (continued)

Option

Description