System message update – Dell PowerEdge 2900 User Manual
Page 10

10
Information Update
System Message Update
Table 1-1 lists new system messages for the PowerEdge 2900 III system 
and the probable cause and corrective action if the message appears.
CAUTION:
Only trained service technicians are authorized to remove the system
cover and access any of the components inside the system. See your Product 
Information Guide for complete information about safety precautions, 
working inside the computer, and protecting against electrostatic discharge
Table 1-1.
System Messages
Message
Causes
Corrective Actions
Alert! Node
Interleaving
disabled! Memory
configuration does
not support Node
Interleaving.
The memory configuration 
does not support node 
interleaving, or the 
configuration has changed 
(for example, a failed 
DIMM) so that node 
interleaving cannot be 
supported.
The system
runs but with reduced 
functionality.
Ensure that the memory 
modules are installed in a 
configuration that supports 
node interleaving. Check 
other system messages 
for additional information 
for possible causes. 
For memory configuration 
information, see 
“General Memory Module 
Installation Guidelines” 
in the Hardware Owner’s 
Manual. If the problem 
persists, see 
“Troubleshooting System 
Memory” in the Hardware 
Owner’s Manual.
!!*** Error: Remote
Access Controller
initialization
failure *** RAC
virtual USB devices
may not be
available...
Remote Access Controller 
initialization failure
Ensure that the Remote 
Access Controller is 
properly installed. See 
“Installing a RAC Card” 
in the Hardware Owner’s 
Manual. 
Invalid PCIe
card found in the
Internal_Storage
slot!
The system halted because 
an invalid PCIe expansion 
card is installed in the 
dedicated storage controller 
slot. 
Remove the PCIe expansion 
card and install the internal 
SAS controller in the 
dedicated slot.