beautypg.com

Dell PowerEdge 2900 User Manual

Page 11

background image

Information Update

11

No boot device

available

Faulty or missing optical
drive subsystem, hard drive,
or hard-drive subsystem, or
no bootable USB key
installed.

Use a bootable USB key,
CD, or hard drive. See
“Using the System Setup
Program” in the

Hardware

Owner’s Manual for
information on setting
the order of boot devices.

PCI BIOS failed

to install

PCIe device BIOS (Option
ROM) checksum failure
detected during shadowing.

Cables to expansion card(s)
loose; faulty or improperly
installed expansion card(s).

Reseat the expansion
card(s). Ensure that all
appropriate cables are
securely connected to the
expansion card(s). If the
problem persists, see
“Troubleshooting System
Expansion Cards” in the
Hardware Owner’s Manual.

PCIe Degraded

Link Width Error:

Embedded device

Expected Link

Width is n

Actual Link

Width is n

Faulty system board
or riser board.

See “Getting Help” in the
Hardware Owner’s Manual.

PCIe Degraded

Link Width Error:

Integrated device

Expected Link

Width is n

Actual Link

Width is n

The specified PCIe device is
faulty or improperly
installed.

For a SAS controller
daughter card, reseat the
card in the dedicated PCIe
connector. See “Installing
a SAS Controller Daughter
Card” in the

Hardware

Owner’s Manual. If the
problem persists, see
“Getting Help” in the
Hardware Owner’s Manual.

Table 1-1. System Messages (continued)

Message

Causes