Dell POWEREDGE 1950 User Manual
Page 16

16
Information Update
Table 1-2.
LCD Status Messages
Code
Text
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character
string that can be
defined by the user
in the System Setup
program.
The SYSTEM NAME
is displayed under
the following
conditions:
• The system is
powered on.
• The power is off
and active errors
are displayed.
This message is for
information only.
You can change the
system ID and
name in the System
Setup program. See
"Using the System
Setup Program" in
the
Hardware
Owner’s Manual.
E1000
FAILSAFE, Call
Support
Check the system
event log for critical
failure events.
See "Getting Help"
in the
Hardware
Owner’s Manual.
E1118
CPU Temp
Interface
The BMC is unable
to determine
the CPU(s)
temperature status.
Consequently, the
BMC increases
the CPU fan speed
to maximum
as a precautionary
measure.
Turn off power to
the system and
restart the system.
If the problem
persists, see
"Getting Help"
in the
Hardware
Owner’s Manual.
E1211
ROMB Batt
RAID battery is
either missing, bad,
or unable to
recharge due to
thermal issues.
Reseat the RAID
battery connector.
See the "RAID
Battery" and see
"Troubleshooting
System Cooling
Problems" in the
Hardware Owner’s
Manual.