Dell POWEREDGE 1950 User Manual
Page 11
Information Update
11
Table 1-1.
System Messages
Message
Causes
Corrective Actions
Alert! Node
Interleaving
disabled! Memory
configuration does
not support Node
Interleaving.
The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a failed
DIMM) so that node
interleaving cannot be
supported. The system
runs but with reduced
functionality.
Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information
for possible causes. For
memory configuration
information, see "General
Memory Module
Installation Guidelines"
in the
Hardware Owner’s
Manual. If the problem
persists, see
"Troubleshooting System
Memory" in the
Hardware
Owner’s Manual.
!!*** Error: Remote
Access Controller
initialization
failure *** RAC
virtual USB devices
may not be
available...
Remote Access Controller
initialization failure.
Ensure that the Remote
Access Controller is
properly installed. See
"Installing a RAC Card"
in the
Hardware Owner’s
Manual.
Invalid PCIe card
found in the
Internal_Storage
slot!
The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage
controller slot.
Remove the PCIe
expansion card and install
the internal SAS controller
in the dedicated slot.
No boot device
available
Faulty or missing optical
drive subsystem, hard
drive, or hard-drive
subsystem, or no bootable
USB key installed.
Use a bootable USB key,
CD, or hard drive. See
"Using the System Setup
Program" in the
Hardware
Owner’s Manual for
information on setting
the order of boot devices.