beautypg.com

Dell POWEREDGE 1950 User Manual

Page 11

background image

Information Update

11

Table 1-1.

System Messages

Message

Causes

Corrective Actions

Alert! Node

Interleaving

disabled! Memory

configuration does

not support Node

Interleaving.

The memory configuration
does not support node
interleaving, or the
configuration has changed
(for example, a failed
DIMM) so that node
interleaving cannot be
supported. The system
runs but with reduced
functionality.

Ensure that the memory
modules are installed in a
configuration that supports
node interleaving. Check
other system messages for
additional information
for possible causes. For
memory configuration
information, see "General
Memory Module
Installation Guidelines"
in the

Hardware Owner’s

Manual. If the problem
persists, see
"Troubleshooting System
Memory" in the

Hardware

Owner’s Manual.

!!*** Error: Remote

Access Controller

initialization

failure *** RAC

virtual USB devices

may not be

available...

Remote Access Controller
initialization failure.

Ensure that the Remote
Access Controller is
properly installed. See
"Installing a RAC Card"
in the

Hardware Owner’s

Manual.

Invalid PCIe card

found in the

Internal_Storage

slot!

The system halted because
an invalid PCIe expansion
card is installed in the
dedicated storage
controller slot.

Remove the PCIe
expansion card and install
the internal SAS controller
in the dedicated slot.

No boot device

available

Faulty or missing optical
drive subsystem, hard
drive, or hard-drive
subsystem, or no bootable
USB key installed.

Use a bootable USB key,
CD, or hard drive. See
"Using the System Setup
Program" in the

Hardware

Owner’s Manual for
information on setting
the order of boot devices.