GB - 1

30RA/30RH

Air-cooled liquid chillers and reversible air-to-water heat pumps
with integrated hydronic module

ENGLISH

For the use of the control system, refer to the Pro-Dialog Plus control manual.

Contents

Page

Physical data .................................................................................................................................

2/3

Electrical data ................................................................................................................................

2/3

Dimensions and location of hydraulic connections .......................................................................

4

Clearance and electric cables .......................................................................................................

4

General information and hydronic module ...................................................................................

5

Water connections .........................................................................................................................

6/8

Electrical connections ....................................................................................................................

9

Refrigerant charge .........................................................................................................................

9/10

Electronic control ...........................................................................................................................

10

Start-up ..........................................................................................................................................

11

Compressor replacement ..............................................................................................................

11

Pump replacement ........................................................................................................................

11

Unit protection devices ..................................................................................................................

11/12

Operating limits and operating range ............................................................................................

12

Maintenance ..................................................................................................................................

13

Final recommendations .................................................................................................................

13

Troubleshooting .............................................................................................................................

14

Start-up check list

Start up date _____________________

Equipment sold by: ___________________________________________ Contract No: ____________________________

Installed by: _________________________________________________ Contract No: ____________________________

Site address _______________________________________________________________________________________

Equipment type and serial No:

30RA ___________________________________________________________

30RH ___________________________________________________________

ELECTRICAL DATA:

Supply voltage

Ph 1: ____________ V

Ph 2: ____________ V

Ph 3: _____________ V

Nominal voltage: ____________________________________ V

% network voltage _______________________

Current draw

Ph 1: ____________ A

Ph 2: ____________ A

Ph 3: _____________ A

Control circuit voltage: ________________________________ V

Control circuit fuse _____________________ A

Main circuit breaker rating _____________________________________________________________________________

PHYSICAL DATA:

Coil:

Plate heat exchanger:

Entering air temp.: _______________________

°

C

Entering water temp.: __________________

°

C

Leaving air temp.: _______________________

°

C

Leaving water temp.: __________________

°

C

Pressure drop (water): _________________ kPa

SAFETY DEVICE SETTING:

High pressure switch: cut-out: _____________ kPa

cut-in: _____________________ kPa

Oil level ___________________________________________________________________________________________

OPTIONS:

Commissioning engineer (name) _______________________________________________________________________

Customer agreement

Name: ________________________________

Date: ______________________________

Note: Complete this start-up list at the time of installation

This manual is related to the following products: