Example 2: Procedure when transferring non-harmonizing parameters

Host to Encoder

Encoder to Host

Remarks

Control word

Status word

D3

1

D25-

D28

D0-D24 D30-

D31

D25-

D28

D0 -
D24

1

0

0

x

0 0

1)

Actual

value

Normal operation

2

0

2

20 000

0 0

1)

Actual

value

Host sends value in order to program
resolution (number of revolutions)

3

0

2

20 000

0 0

1)

Actual

value

Host continues to wait for encoder
confirmation

4

0

2

20 000

1 1

1)

20 000 Encoder has taken over parameter and

starts processing

5

0

2

20 000

1 1

1)

20 000 Parameter processing within encoder is

still running

6

0

2

20 000

1 1

2

20 000 Parameter processing has been

finished, encoder remains in
"Parameterization" state

7

0

3

1

1 1

2

20 000 Host sends value to program coding of

actual position value

8

0

3

1

1 1

2

20 000 Host continues to wait for encoder

confirmation

9

0

3

1

1 1

2

1

Encoder has accepted parameter and
starts processing

10 0

3

1

1 1

3

1

Parameter processing has been
finished, encoder remains in
"Parameterization" state

11 1

0

0

1 1

3

1

Device control command "Enable
operation " from Host to encoder.
Encoder shows no reaction yet

12 1

0

0

0 1

1

0

Encoder switches to "Disturbance"
state, the disturbance code is "1". The
actual position value is not allotted on
the process data channel.

Here a try has been made to set the resolution of the encoder to 20 000 revolutions. The encoder reacts to
this inadmissible parameter setting by switching to the "Disturbance" state and by emitting the disturbance
code "1".