8 Contact
description
8.1 Contact description for C-plug
D01, D01
Incoming long-distance bus (A1) galvanically
DI1, DI1
separated from remaining encoder electr.
GNDI
Galvanically separated reference mass for incoming long-distance bus (A1).
Models without electrical isolation combined with GND.
UB
Contacts for encoder supply incorporated
GNDB
within the bus (A1), UB = 10...30 VDC. Current load max. 700 mA
D02, D02
Relaying long-distance bus (W1)
DI2, DI2
GND
Reference mass for relaying long-distance bus (W1)
UB
Contacts for encoder supply within bus
GNDB
(W1), UB = 10 ... 30 VDC. Connected internally with UB/GND B from A1
PE
Screening combined with encoder housing
RBST
Recognition of further bus users
Open contact: Last user
Contact to GND: User X
8.2 Pin assignment for C-plug
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Incoming interface
Outgoing interface
(pin)
(socket)
Pin
Assignment
Pin
Assignment
1 D01
1 D02
2 D01
2 D02
3 DI1
3 DI2
4 DI1
4 DI2
5 GNDI
5 GND
6 PE
6 PE
7 UB
7 UB
8 GNDB
8 GNDB
9 –
9 RBST