Caution, Warning, Step 3 — cleaning burners – Carrier 58MEC User Manual

Page 5

background image

5

COLLECTOR BOX

TUBE (PINK)

COLLECTOR BOX

TUBE (GREEN)

INDUCER HOUSING

(MOLDED) DRAIN

TUBE (BEHIND

COLLECTOR BOX

DRAIN TUBE)

COLLECTOR BOX

DRAIN TUBE (BLUE)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (LEFT

DRAIN OPTION)

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

FIELD-INSTALLED

FACTORY-SUPPLIED

1

2

-IN. CPVC STREET

ELBOWS (2) FOR

LEFT DRAIN OPTION

FIELD-INSTALLED

FACTORY-SUPPLIED

DRAIN TUBE

COUPLING (RIGHT

DRAIN OPTION)

CAP

COLLECTOR BOX

DRAIN TUBE (BLUE

& WHITE STRIPED)

PLUG

CONDENSATE
TRAP

A01030

Fig. 5 -- Factory--Shipped Upflow Tube Configuration

(Shown with Blower Access Panel Removed)

UNIT DAMAGE HAZARD
Failure to follow this caution may result in noise or furnace

component failure.
The blower wheel should not be dropped or bent as balance

will be affected.

CAUTION

!

g. Clean wheel per instructions on degreaser cleaner. Do

not get degreaser in motor.

9. Reassemble motor and blower wheel by reversing items 8b

through 8f. Ensure wheel is positioned for proper rotation.
Tighten setscrew to between 140--160 in.--lb torque.

NOTE: Be sure to attach ground wire to blower housing.

10. Reinstall blower assembly in furnace.
11. Reinstall control box, transformer, and door switch as-

sembly on blower shelf.

12. Reinstall condensate trap and tubing if previously removed.

a. Reinstall condensate trap in hole in blower shelf.

b. Connect condensate trap drain tubes. See Fig. 5 or

tubing diagram on main furnace door for proper tube

location.

(1.) Connect 1 tube (blue or blue and white striped)

from collector box.

(2.) Connect 1 tube (violet or unmarked) from inducer

housing.

(3.) Connect 1 tube (relief port, green or pink) from

collector box.

NOTE: Ensure tubes are not kinked or pinched, as this will affect
operation.

c. Connect field drain to condensate trap.

13. Reconnect wires.

Refer to furnace wiring diagram and connect thermostat leads if
previously disconnected. (See Fig. 16.)
NOTE: Refer to Table 3 for motor speed lead reconnection if
leads were not identified before disconnection.

UNIT DAMAGE HAZARD
Failure follow this caution may result in unit component

damage.
Heating air speed selection MUST be adjusted to provide

proper temperature rise as specified on the rating plate.

CAUTION

!

Table 3 – Speed Selection

COLOR

SPEED

FACTORY

ATTACHED TO

Gray

5

Cool

Yellow

4

Spare

Blue

3

High---Heat

Orange

2

Spare

Red

1

Low Heat/Cont

Fan

ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury

or death.
Blower access door switch opens 115--v power to furnace

control. No component operation can occur. Caution must be

taken when manually closing this switch for service purposes.

!

WARNING

14. Turn on electrical supply. Manually close blower access

door switch. Use a piece of tape to hold switch closed.

Check for proper rotation and speed changes by performing
a component self--test as shown at the bottom of Service la-

bel. (See Fig. 21.)

15. If furnace is operating properly, remove tape to release

blower access door switch, replace blower access door, and

replace main furnace door.

Step 3 — Cleaning Burners

The following items should be performed by a qualified service

technician. If the burners develop an accumulation of light dirt or
dust, they may be cleaned by using the following procedure:

1. Turn off gas and electrical supplies to furnace.
2. Remove main furnace door.
3. Remove burner box cover.
4. Using backup wrench, disconnect gas supply pipe from fur-

nace gas control valve.

58ME

C