Automatic water softener – EcoPure MW_MW40_450216 User Manual
Page 20
..................................................AUTOMATIC WATER SOFTENER
MW-40 DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, continued
setting: MODEL CODE, 12 OR 24 HOUR CLOCK, AND GALLONS OR LITERS MEASURE .....
NOTE: The model code is factory set at assembly and testing. The hour clock and water measure have factory set
default values. The defaults are: 12 or 24 hour clock - 12; Gallons or liters measure - gallons. The model code should
never require resetting, but to check, or to set if previously omitted, read below. The defaults suit most installations.
However, to make a change, read and do the following.
MODEL CODE: The timer must have the right model
code set to operate the softener correctly. The correct
code setting is:
! For model MW-40, it must show A-31.
If A- - - is flashing in the display, do steps 2, 3, 5 and
7.
12 OR 24 HOUR CLOCK: With 12 hr set, all time
displays are in standard clock time... 12:00AM to
11:59PM. If 24 hr is set, time displays are in military
time... 0100 (1:00AM) to 0000 (midnight). To change
from the 12 hr setting, do steps 1, 3, 4, 5 and 7.
GALLONS OR LITERS MEASURE: All water flow
rate and usage displays are in gallons with the default
GALS setting. If reset to liters, the same displays are
shown in liters. Use steps 1, 3, 5, 6 and 7 to change.
1. Beginning from the present
time display, press and hold in
the SET button until 2:00 AM
(or as otherwise set), and
RECHARGE TIME begin to
flash.
2. Press and hold in the SET
button again. Either A- - - or
a previously set code will
appear. If setting is needed,
use the up or down button to
set A-31 as needed.
3. Press SET to select and move to next screen.
4. 12 hr flashes along with
TIME. To change the display
to 24hr, use the up button. Use
the down button to reset to
12hr.
5. Press SET to select and move to next screen.
6. GALS flashes, along with
GALLONS. Use the up button
to change to the liter setting.
Use the down button to return
to the gallon setting.
7. Press the SET button a final time to return to the
present time display.
20